Cerebrospinal fluid elemental analysis by using a total sample consumption system operated at high temperature adapted to inductively coupled plasma mass spectrometry

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/69910
Información del item - Informació de l'item - Item information
Títol: Cerebrospinal fluid elemental analysis by using a total sample consumption system operated at high temperature adapted to inductively coupled plasma mass spectrometry
Autors: Cañabate López, Águeda | García-Ruiz, Esperanza | Resano, Martín | Todolí Torró, José Luis
Grups d'investigació o GITE: Análisis de Polímeros y Nanomateriales
Centre, Departament o Servei: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología
Paraules clau: Cerebrospinal fluids | Total sample consumption system | High temperature | Inductively coupled plasma mass spectrometry
Àrees de coneixement: Química Analítica
Data de publicació: 20-de juliol-2017
Editor: Royal Society of Chemistry
Citació bibliogràfica: Journal of Analytical Atomic Spectrometry. 2017, 32: 1916-1924. doi:10.1039/C7JA00210F
Resum: A total consumption low sample introduction system has been applied for the first time to the multielement analysis of non-diluted cerebrospinal fluids (CSFs) by means of inductively coupled plasma mass spectrometry (ICP-MS). A 2.5 μL sample volume has been injected into an air carrier stream in agreement with the air-segmented injection principle. The sample plug has been turned into an aerosol by means of a high efficiency nebulizer (HEN) and further introduced into the so-called high temperature torch integrated sample introduction system (hTISIS). A transient signal has been thus obtained. For spiked CSF real samples it has been verified that the higher the temperature, the greater the sensitivity. Under optimized conditions, the hTISIS provides peak areas around four times higher than those provided by the spectrometer default device (i.e., a double pass spray chamber). Additional advantages provided by the former system include limits of detection up to 6 times lower and narrower peaks as compared to those reported for the double pass spray chamber. Furthermore, the use of the hTISIS is not detrimental from the point of view oxide production and doubly charged ion generation. Regarding the extent of non-spectral interference caused by the CSF matrix, it has been verified that, with the hTISIS, recoveries for spiked real samples were close to 100% for a set of 14 different elements (V, Cr, Mn, Co, Ni, Cu, As, Se, Mo, Cd, Sb, Ba, Tl and Pb). Meanwhile, in segmented flow injection mode, the reference system provided recoveries from 200 to 500%, depending on the element and the sample, thus demonstrating the occurrence of matrix effects.
Patrocinadors: The authors acknowledge the funding from CTQ2015-64684-P (MINECO/FEDER) and from the Aragón Government (Fondo Europeo de Desarrollo Regional). Águeda C. would like to thank the Vice-Presidency for Research of the University of Alicante (ref. UAFPU2015-5990) and the Generalitat Valenciana, Spain (ref. ACIF/2016/042) for the pre-doctoral grants.
URI: http://hdl.handle.net/10045/69910
ISSN: 0267-9477 (Print) | 1364-5544 (Online)
DOI: 10.1039/C7JA00210F
Idioma: eng
Tipus: info:eu-repo/semantics/article
Drets: © The Royal Society of Chemistry 2017
Revisió científica: si
Versió de l'editor: http://dx.doi.org/10.1039/C7JA00210F
Apareix a la col·lecció: INV - NANOBIOPOL - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
Thumbnail2017_Canabate_etal_JAAS_final.pdfVersión final (acceso restringido)1,45 MBAdobe PDFObrir     Sol·licitar una còpia
Thumbnail2017_Canabate_etal_JAAS_accepted.pdfAccepted Manuscript (acceso abierto)646,75 kBAdobe PDFObrir Vista prèvia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.