Determination of siloxanes in water samples employing graphene oxide/Fe3O4 nanocomposite as sorbent for magnetic solid‐phase extraction prior to GC–MS

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/82808
Información del item - Informació de l'item - Item information
Títol: Determination of siloxanes in water samples employing graphene oxide/Fe3O4 nanocomposite as sorbent for magnetic solid‐phase extraction prior to GC–MS
Autors: Costa dos Reis, Luciana | Vidal, Lorena | Canals, Antonio
Grups d'investigació o GITE: Espectroscopía Atómica-Masas y Química Analítica en Condiciones Extremas
Centre, Departament o Servei: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología | Universidad de Alicante. Instituto Universitario de Materiales
Paraules clau: Gas chromatography with mass spectrometry | Magnetic solid-phase extraction | Nanocomposites | Siloxanes | Water samples
Àrees de coneixement: Nutrición y Bromatología | Química Analítica
Data de publicació: 21-de setembre-2018
Editor: Wiley-VCH Verlag GmbH & Co. KGaA
Citació bibliogràfica: Journal of Separation Science. 2018, 41(22): 4177-4184. doi:10.1002/jssc.201800577
Resum: A new, fast, simple, and environmentally friendly analytical method has been developed to determine six siloxanes in water samples: octamethyltrisiloxane, octamethylcyclotetrasiloxane, decamethyltetrasiloxane, decamethylcyclopentasiloxane, dodecamethylpentasiloxane and dodecamethylcyclohexasiloxane. The analytical method consists of magnetic solid‐phase extraction employing graphene oxide/Fe3O4 as sorbent for the separation and preconcentration of siloxanes prior to GC–MS determination. The extraction procedure was optimized by means of a Plackett‐Burman design. Under the optimized extraction conditions (graphene oxide/Fe3O4, 20 mg; extraction time, 10 min; eluent volume, 0.5 mL ACN; elution time, 2.5 min; sample volume, 20 mL), the method rendered repeatability levels with a relative standard deviation between 9 and 20% (n = 6, 10 μg/L). Methodological limits of detection ranged from 0.003 to 0.1 μg/L. The linearity of the method was studied between the methodological limit of quantification and 100 μg/L, obtaining correlation coefficient values between 0.990 and 0.999. The applicability of the method was assessed by analyzing drinking, river and wastewater samples. Relative recovery values ranged between 70 and 120% (1 and 60 μg/L spiking level) showing that the matrix had a negligible effect on extraction. Finally, the greenness of this method was confirmed by the semiquantitative Eco‐Scale metrics.
Patrocinadors: The authors would like to thank “Vicerrectorado de Investigación y Transferencia de Conocimiento” of the University of Alicante (UAUSTI16-04), the Ministry of Science and Innovation of Spain (project no. CTQ2011-23968), the Ministry of Economy, Industry and Competitiveness of Spain (project no. CTQ2016-79991-R, AEI/FEDER, UE) for the financial support. L. Costa thanks the Capes Foundation within the Ministry of Education in Brazil (Process 99999.012013/2013-07).
URI: http://hdl.handle.net/10045/82808
ISSN: 1615-9306 (Print) | 1615-9314 (Online)
DOI: 10.1002/jssc.201800577
Idioma: eng
Tipus: info:eu-repo/semantics/article
Drets: © 2018 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim
Revisió científica: si
Versió de l'editor: https://doi.org/10.1002/jssc.201800577
Apareix a la col·lecció: INV - SP-BG - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
Thumbnail2018_Costa-dos-Reis_etal_JSeparatSci_accepted.pdfAccepted Manuscript (acceso abierto)890,22 kBAdobe PDFObrir Vista prèvia
Thumbnail2018_Costa-dos-Reis_etal_JSeparatSci_final.pdfVersión final (acceso restringido)591,08 kBAdobe PDFObrir     Sol·licitar una còpia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.