Multivariate calibration in Laser-Induced Breakdown Spectroscopy quantitative analysis: The dangers of a ‘black box’ approach and how to avoid them

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/74629
Registre complet
Registre complet
Camp Dublin Core Valor Idioma
dc.contributorEspectroscopía Atómica-Masas y Química Analítica en Condiciones Extremases_ES
dc.contributor.authorSafi, Ali-
dc.contributor.authorCampanella, Beatrice-
dc.contributor.authorGrifoni, Emanuela-
dc.contributor.authorLegnaioli, Stefano-
dc.contributor.authorLorenzetti, Giulia-
dc.contributor.authorPagnotta, Stefano-
dc.contributor.authorPoggialini, Francesco-
dc.contributor.authorRipoll-Seguer, Laura-
dc.contributor.authorHidalgo, Montserrat-
dc.contributor.authorPalleschi, Vincenzo-
dc.contributor.otherUniversidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatologíaes_ES
dc.contributor.otherUniversidad de Alicante. Instituto Universitario de Materialeses_ES
dc.date.accessioned2018-03-28T07:56:55Z-
dc.date.available2018-03-28T07:56:55Z-
dc.date.issued2018-06-
dc.identifier.citationSpectrochimica Acta Part B: Atomic Spectroscopy. 2018, 144: 46-54. doi:10.1016/j.sab.2018.03.007es_ES
dc.identifier.issn0584-8547 (Print)-
dc.identifier.issn1873-3565 (Online)-
dc.identifier.urihttp://hdl.handle.net/10045/74629-
dc.description.abstractThe introduction of multivariate calibration curve approach in Laser-Induced Breakdown Spectroscopy (LIBS) quantitative analysis has led to a general improvement of the LIBS analytical performances, since a multivariate approach allows to exploit the redundancy of elemental information that are typically present in a LIBS spectrum. Software packages implementing multivariate methods are available in the most diffused commercial and open source analytical programs; in most of the cases, the multivariate algorithms are robust against noise and operate in unsupervised mode. The reverse of the coin of the availability and ease of use of such packages is the (perceived) difficulty in assessing the reliability of the results obtained which often leads to the consideration of the multivariate algorithms as ‘black boxes’ whose inner mechanism is supposed to remain hidden to the user. In this paper, we will discuss the dangers of a ‘black box’ approach in LIBS multivariate analysis, and will discuss how to overcome them using the chemical-physical knowledge that is at the base of any LIBS quantitative analysis.es_ES
dc.languageenges_ES
dc.publisherElsevieres_ES
dc.rights© 2018 Elsevier B.V.es_ES
dc.subjectLIBSes_ES
dc.subjectCast irones_ES
dc.subjectCalibration curves, Partial Least Squares Analysises_ES
dc.subjectArtificial Neural Networkses_ES
dc.subject.otherQuímica Analíticaes_ES
dc.titleMultivariate calibration in Laser-Induced Breakdown Spectroscopy quantitative analysis: The dangers of a ‘black box’ approach and how to avoid themes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.peerreviewedsies_ES
dc.identifier.doi10.1016/j.sab.2018.03.007-
dc.relation.publisherversionhttps://doi.org/10.1016/j.sab.2018.03.007es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
Apareix a la col·lecció: INV - SP-BG - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
Thumbnail2018_Safi_etal_SpectrActaB_final.pdfVersión final (acceso restringido)1,69 MBAdobe PDFObrir     Sol·licitar una còpia
Thumbnail2018_Safi_etal_SpectrActaB_accepted.pdfAccepted Manuscript (acceso abierto)1,2 MBAdobe PDFObrir Vista prèvia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.