Clinical Outcomes With a New Continuous Range of Vision Presbyopia-Correcting Intraocular Lens
Empreu sempre aquest identificador per citar o enllaçar aquest ítem
http://hdl.handle.net/10045/115073
Títol: | Clinical Outcomes With a New Continuous Range of Vision Presbyopia-Correcting Intraocular Lens |
---|---|
Autors: | Gabrić, Nikica | Gabrić, Ivan | Gabrić, Krešimir | Biščević, Alma | Piñero, David P. | Bohač, Maja |
Grups d'investigació o GITE: | Grupo de Óptica y Percepción Visual (GOPV) |
Centre, Departament o Servei: | Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía |
Paraules clau: | Presbyopia-correcting | Intraocular lens | Continuous range of vision | Clinical outcomes |
Àrees de coneixement: | Óptica |
Data de publicació: | 1-d’abril-2021 |
Editor: | SLACK Incorporated |
Citació bibliogràfica: | Journal of Refractive Surgery. 2021, 37(4): 256-262. https://doi.org/10.3928/1081597X-20210209-01 |
Resum: | PURPOSE: To evaluate the clinical outcomes including patient-reported outcome measures in a sample of eyes undergoing bilateral cataract surgery with implantation of a new model of presbyopia-correcting intraocular lens (IOL). METHODS: This non-randomized prospective case series enrolled 206 eyes of 103 patients undergoing phacoemulsification cataract surgery with bilateral implantation of the TECNIS Synergy IOL (Johnson & Johnson Vision). High and low contrast visual acuity, refractive, defocus curve, and patient-reported visual performance (Catquest-9SF questionnaire) outcomes were evaluated during a 3-month follow-up. RESULTS: A total of 96.1% (99 of 103) and 91.3% (94 of 103) of patients achieved binocular postoperative uncorrected distance (UDVA) and near visual acuity (UNVA) of 0.00 logMAR (20/20), respectively. Mean postoperative mesopic UNVA for both eyes was 0.14 ± 0.03 logMAR. Likewise, mean binocular UDVA and UNVA were 0.00 ± 0.03 and 0.04 ± 0.02 logMAR. An almost flat mean defocus curve was obtained, with visual acuities between 0.00 and 0.10 logMAR for most defocus levels in both eyes. A reduction of contrast led to a limited but statistically significant change in UNVA in both eyes (P < .001). The Rasch calibrated scoring of item 2 and the Rasch calibrated mean score of the Catquest-9SF questionnaire increased significantly with surgery (P < .001). CONCLUSIONS: This new presbyopia-correcting IOL provides a continuous range of functional focus, with a limited deterioration under mesopic conditions, which is perceived as a satisfactory outcome by the patient if proper patient selection is performed. |
Patrocinadors: | Supported by an unrestricted research grant from Johnson & Johnson Vision. |
URI: | http://hdl.handle.net/10045/115073 |
ISSN: | 1081-597X (Print) | 1938-2391 (Online) |
DOI: | 10.3928/1081597X-20210209-01 |
Idioma: | eng |
Tipus: | info:eu-repo/semantics/article |
Drets: | © SLACK Incorporated |
Revisió científica: | si |
Versió de l'editor: | https://doi.org/10.3928/1081597X-20210209-01 |
Apareix a la col·lecció: | INV - GOPV - Artículos de Revistas |
Arxius per aquest ítem:
Arxiu | Descripció | Tamany | Format | |
---|---|---|---|---|
Gabric_etal_2021_JRefractSurg_final.pdf | Versión final (acceso restringido) | 3,36 MB | Adobe PDF | Obrir Sol·licitar una còpia |
Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.