Clinical Outcomes With a New Continuous Range of Vision Presbyopia-Correcting Intraocular Lens

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/115073
Información del item - Informació de l'item - Item information
Títol: Clinical Outcomes With a New Continuous Range of Vision Presbyopia-Correcting Intraocular Lens
Autors: Gabrić, Nikica | Gabrić, Ivan | Gabrić, Krešimir | Biščević, Alma | Piñero, David P. | Bohač, Maja
Grups d'investigació o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centre, Departament o Servei: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Paraules clau: Presbyopia-correcting | Intraocular lens | Continuous range of vision | Clinical outcomes
Àrees de coneixement: Óptica
Data de publicació: 1-d’abril-2021
Editor: SLACK Incorporated
Citació bibliogràfica: Journal of Refractive Surgery. 2021, 37(4): 256-262. https://doi.org/10.3928/1081597X-20210209-01
Resum: PURPOSE: To evaluate the clinical outcomes including patient-reported outcome measures in a sample of eyes undergoing bilateral cataract surgery with implantation of a new model of presbyopia-correcting intraocular lens (IOL). METHODS: This non-randomized prospective case series enrolled 206 eyes of 103 patients undergoing phacoemulsification cataract surgery with bilateral implantation of the TECNIS Synergy IOL (Johnson & Johnson Vision). High and low contrast visual acuity, refractive, defocus curve, and patient-reported visual performance (Catquest-9SF questionnaire) outcomes were evaluated during a 3-month follow-up. RESULTS: A total of 96.1% (99 of 103) and 91.3% (94 of 103) of patients achieved binocular postoperative uncorrected distance (UDVA) and near visual acuity (UNVA) of 0.00 logMAR (20/20), respectively. Mean postoperative mesopic UNVA for both eyes was 0.14 ± 0.03 logMAR. Likewise, mean binocular UDVA and UNVA were 0.00 ± 0.03 and 0.04 ± 0.02 logMAR. An almost flat mean defocus curve was obtained, with visual acuities between 0.00 and 0.10 logMAR for most defocus levels in both eyes. A reduction of contrast led to a limited but statistically significant change in UNVA in both eyes (P < .001). The Rasch calibrated scoring of item 2 and the Rasch calibrated mean score of the Catquest-9SF questionnaire increased significantly with surgery (P < .001). CONCLUSIONS: This new presbyopia-correcting IOL provides a continuous range of functional focus, with a limited deterioration under mesopic conditions, which is perceived as a satisfactory outcome by the patient if proper patient selection is performed.
Patrocinadors: Supported by an unrestricted research grant from Johnson & Johnson Vision.
URI: http://hdl.handle.net/10045/115073
ISSN: 1081-597X (Print) | 1938-2391 (Online)
DOI: 10.3928/1081597X-20210209-01
Idioma: eng
Tipus: info:eu-repo/semantics/article
Drets: © SLACK Incorporated
Revisió científica: si
Versió de l'editor: https://doi.org/10.3928/1081597X-20210209-01
Apareix a la col·lecció: INV - GOPV - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
ThumbnailGabric_etal_2021_JRefractSurg_final.pdfVersión final (acceso restringido)3,36 MBAdobe PDFObrir     Sol·licitar una còpia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.