Soft multifocal simultaneous image contact lenses: a review
Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/10045/66501
Título: | Soft multifocal simultaneous image contact lenses: a review |
---|---|
Autor/es: | Pérez-Prados, Roque | Piñero, David P. | Pérez Cambrodí, Rafael J. | Madrid-Costa, David |
Grupo/s de investigación o GITE: | Grupo de Óptica y Percepción Visual (GOPV) |
Centro, Departamento o Servicio: | Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía |
Palabras clave: | Defocus curve | Multifocal | Power profile | Pupil | Questionnaires | Spherical aberration |
Área/s de conocimiento: | Óptica |
Fecha de publicación: | mar-2017 |
Editor: | Wiley |
Cita bibliográfica: | Clinical and Experimental Optometry. 2017, 100(2): 107-127. doi:10.1111/cxo.12488 |
Resumen: | Soft multifocal simultaneous image contact lenses have boomed in recent years due to the growing number of presbyopic patients demanding visual solutions, allowing them to maintain their current standard of living. The concept of ‘simultaneous image’ is based on blur interpretation and/or blur tolerance of superimposed multiple images on the retina formed by various powers of a contact lens. This is the basis for a specific type of multifocal contact lens developed for the compensation of presbyopia. Manufacturers have released a great variety of soft simultaneous image lens designs to meet different patient needs but their fitting is still unsatisfactory in some cases. Some presbyopes discontinue wearing contact lenses due to some limitations in visual quality and comfort that can be overcome with an appropriate contact lens selection based on a comprehensive pre-fitting evaluation. This paper aims to review the different types of soft multifocal contact lenses that are currently available for presbyopic correction and to define the steps and factors crucial for their fitting, such as pupil, aberrations, accommodation and centring. A discussion about useful tools to achieve a customised fitting leading to a successful outcome, such as the defocus curve, power profile and questionnaires, is performed. |
URI: | http://hdl.handle.net/10045/66501 |
ISSN: | 0816-4622 (Print) | 1444-0938 (Online) |
DOI: | 10.1111/cxo.12488 |
Idioma: | eng |
Tipo: | info:eu-repo/semantics/article |
Derechos: | © 2016 Optometry Australia |
Revisión científica: | si |
Versión del editor: | http://dx.doi.org/10.1111/cxo.12488 |
Aparece en las colecciones: | INV - GOPV - Artículos de Revistas |
Archivos en este ítem:
Archivo | Descripción | Tamaño | Formato | |
---|---|---|---|---|
2017_Perez-Prados_etal_ClinExpOptom_final.pdf | Versión final (acceso restringido) | 960,27 kB | Adobe PDF | Abrir Solicitar una copia |
Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.