Soft multifocal simultaneous image contact lenses: a review

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/66501
Información del item - Informació de l'item - Item information
Título: Soft multifocal simultaneous image contact lenses: a review
Autor/es: Pérez-Prados, Roque | Piñero, David P. | Pérez Cambrodí, Rafael J. | Madrid-Costa, David
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Defocus curve | Multifocal | Power profile | Pupil | Questionnaires | Spherical aberration
Área/s de conocimiento: Óptica
Fecha de publicación: mar-2017
Editor: Wiley
Cita bibliográfica: Clinical and Experimental Optometry. 2017, 100(2): 107-127. doi:10.1111/cxo.12488
Resumen: Soft multifocal simultaneous image contact lenses have boomed in recent years due to the growing number of presbyopic patients demanding visual solutions, allowing them to maintain their current standard of living. The concept of ‘simultaneous image’ is based on blur interpretation and/or blur tolerance of superimposed multiple images on the retina formed by various powers of a contact lens. This is the basis for a specific type of multifocal contact lens developed for the compensation of presbyopia. Manufacturers have released a great variety of soft simultaneous image lens designs to meet different patient needs but their fitting is still unsatisfactory in some cases. Some presbyopes discontinue wearing contact lenses due to some limitations in visual quality and comfort that can be overcome with an appropriate contact lens selection based on a comprehensive pre-fitting evaluation. This paper aims to review the different types of soft multifocal contact lenses that are currently available for presbyopic correction and to define the steps and factors crucial for their fitting, such as pupil, aberrations, accommodation and centring. A discussion about useful tools to achieve a customised fitting leading to a successful outcome, such as the defocus curve, power profile and questionnaires, is performed.
URI: http://hdl.handle.net/10045/66501
ISSN: 0816-4622 (Print) | 1444-0938 (Online)
DOI: 10.1111/cxo.12488
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2016 Optometry Australia
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1111/cxo.12488
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2017_Perez-Prados_etal_ClinExpOptom_final.pdfVersión final (acceso restringido)960,27 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.