Clinical utility of ocular residual astigmatism and topographic disparity vector indexes in subclinical and clinical keratoconus

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/53453
Información del item - Informació de l'item - Item information
Title: Clinical utility of ocular residual astigmatism and topographic disparity vector indexes in subclinical and clinical keratoconus
Authors: Piñero, David P. | Pérez Cambrodí, Rafael J. | Soto-Negro, Roberto | Ruiz Fortes, Pedro | Artola, Alberto
Research Group/s: Grupo de Óptica y Percepción Visual (GOPV)
Center, Department or Service: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Keywords: Keratoconus | Ocular residual astigmatism | Corneal topography | Topography disparity | Corneal astigmatism
Knowledge Area: Óptica
Issue Date: Dec-2015
Publisher: Springer Berlin Heidelberg
Citation: Graefe's Archive for Clinical and Experimental Ophthalmology. 2015, 253(12): 2229-2237. doi:10.1007/s00417-015-3169-x
Abstract: Purpose. We aimed to characterize the distribution of the vector parameters ocular residual astigmatism (ORA) and topography disparity (TD) in a sample of clinical and subclinical keratoconus eyes, and to evaluate their diagnostic value to discriminate between these conditions and healthy corneas. Methods. This study comprised a total of 43 keratoconic eyes (27 patients, 17–73 years) (keratoconus group), 11 subclinical keratoconus eyes (eight patients, 11–54 years) (subclinical keratoconus group) and 101 healthy eyes (101 patients, 15–64 years) (control group). In all cases, a complete corneal analysis was performed using a Scheimpflug photography-based topography system. Anterior corneal topographic data was imported from it to the iASSORT software (ASSORT Pty. Ltd), which allowed the calculation of ORA and TD. Results. Mean magnitude of the ORA was 3.23 ± 2.38, 1.16 ± 0.50 and 0.79 ± 0.43 D in the keratoconus, subclinical keratoconus and control groups, respectively (p < 0.001). Mean magnitude of the TD was 9.04 ± 8.08, 2.69 ± 2.42 and 0.89 ± 0.50 D in the keratoconus, subclinical keratoconus and control groups, respectively (p < 0.001). Good diagnostic performance of ORA (cutoff point: 1.21 D, sensitivity 83.7 %, specificity 87.1 %) and TD (cutoff point: 1.64 D, sensitivity 93.3 %, specificity 92.1 %) was found for the detection of keratoconus. The diagnostic ability of these parameters for the detection of subclinical keratoconus was more limited (ORA: cutoff 1.17 D, sensitivity 60.0 %, specificity 84.2 %; TD: cutoff 1.29 D, sensitivity 80.0 %, specificity 80.2 %). Conclusion. The vector parameters ORA and TD are able to discriminate with good levels of precision between keratoconus and healthy corneas. For the detection of subclinical keratoconus, only TD seems to be valid.
URI: http://hdl.handle.net/10045/53453
ISSN: 0721-832X (Print) | 1435-702X (Online)
DOI: 10.1007/s00417-015-3169-x
Language: eng
Type: info:eu-repo/semantics/article
Rights: © Springer-Verlag Berlin Heidelberg 2015. The final publication is available at Springer via http://dx.doi.org/10.1007/s00417-015-3169-x
Peer Review: si
Publisher version: http://dx.doi.org/10.1007/s00417-015-3169-x
Appears in Collections:INV - GOPV - Artículos de Revistas
INV - GIOptom - Artículos de Revistas

Files in This Item:
Files in This Item:
File Description SizeFormat 
Thumbnail2015_Pinero_etal_Graefes_final.pdfVersión final (acceso restringido)844,71 kBAdobe PDFOpen    Request a copy


Items in RUA are protected by copyright, with all rights reserved, unless otherwise indicated.