Clinical utility of ocular residual astigmatism and topographic disparity vector indexes in subclinical and clinical keratoconus

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/53453
Información del item - Informació de l'item - Item information
Título: Clinical utility of ocular residual astigmatism and topographic disparity vector indexes in subclinical and clinical keratoconus
Autor/es: Piñero, David P. | Pérez Cambrodí, Rafael J. | Soto-Negro, Roberto | Ruiz Fortes, Pedro | Artola, Alberto
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Keratoconus | Ocular residual astigmatism | Corneal topography | Topography disparity | Corneal astigmatism
Área/s de conocimiento: Óptica
Fecha de publicación: dic-2015
Editor: Springer Berlin Heidelberg
Cita bibliográfica: Graefe's Archive for Clinical and Experimental Ophthalmology. 2015, 253(12): 2229-2237. doi:10.1007/s00417-015-3169-x
Resumen: Purpose. We aimed to characterize the distribution of the vector parameters ocular residual astigmatism (ORA) and topography disparity (TD) in a sample of clinical and subclinical keratoconus eyes, and to evaluate their diagnostic value to discriminate between these conditions and healthy corneas. Methods. This study comprised a total of 43 keratoconic eyes (27 patients, 17–73 years) (keratoconus group), 11 subclinical keratoconus eyes (eight patients, 11–54 years) (subclinical keratoconus group) and 101 healthy eyes (101 patients, 15–64 years) (control group). In all cases, a complete corneal analysis was performed using a Scheimpflug photography-based topography system. Anterior corneal topographic data was imported from it to the iASSORT software (ASSORT Pty. Ltd), which allowed the calculation of ORA and TD. Results. Mean magnitude of the ORA was 3.23 ± 2.38, 1.16 ± 0.50 and 0.79 ± 0.43 D in the keratoconus, subclinical keratoconus and control groups, respectively (p < 0.001). Mean magnitude of the TD was 9.04 ± 8.08, 2.69 ± 2.42 and 0.89 ± 0.50 D in the keratoconus, subclinical keratoconus and control groups, respectively (p < 0.001). Good diagnostic performance of ORA (cutoff point: 1.21 D, sensitivity 83.7 %, specificity 87.1 %) and TD (cutoff point: 1.64 D, sensitivity 93.3 %, specificity 92.1 %) was found for the detection of keratoconus. The diagnostic ability of these parameters for the detection of subclinical keratoconus was more limited (ORA: cutoff 1.17 D, sensitivity 60.0 %, specificity 84.2 %; TD: cutoff 1.29 D, sensitivity 80.0 %, specificity 80.2 %). Conclusion. The vector parameters ORA and TD are able to discriminate with good levels of precision between keratoconus and healthy corneas. For the detection of subclinical keratoconus, only TD seems to be valid.
URI: http://hdl.handle.net/10045/53453
ISSN: 0721-832X (Print) | 1435-702X (Online)
DOI: 10.1007/s00417-015-3169-x
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © Springer-Verlag Berlin Heidelberg 2015. The final publication is available at Springer via http://dx.doi.org/10.1007/s00417-015-3169-x
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1007/s00417-015-3169-x
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2015_Pinero_etal_Graefes_final.pdfVersión final (acceso restringido)844,71 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.