Intrasubject repeatability in keratoconus-eye measurements obtained with a new Scheimpflug photography–based system

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/39223
Información del item - Informació de l'item - Item information
Títol: Intrasubject repeatability in keratoconus-eye measurements obtained with a new Scheimpflug photography–based system
Autors: Montalbán, Raúl | Alió, Jorge L. | Javaloy, Jaime | Piñero, David P.
Grups d'investigació o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centre, Departament o Servei: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Paraules clau: Keratoconus eyes | Intrasubject repeatability | Scheimpflug-photography | Placido-disk technology | Topography system
Àrees de coneixement: Óptica
Data de publicació: de febrer-2013
Editor: Elsevier
Citació bibliogràfica: Journal of Cataract & Refractive Surgery. 2013, 39(2): 211-218. doi:10.1016/j.jcrs.2012.10.033
Resum: Purpose: To evaluate in keratoconus eyes the intrasubject repeatability of anterior and posterior corneal curvature and of other anterior segment anatomic measurements obtained with a new topography system combining Scheimpflug-photography and Placido-disk technology. Setting: Vissum Corporation, Alicante, Spain. Design: Evaluation of technology. Methods: All keratoconus eyes had a comprehensive ophthalmologic examination including analysis with the Sirius system. Three consecutive measurements were obtained to assess the intrasubject repeatability of the following parameters: anterior and posterior corneal curvature and shape factor, white-to-white (WTW) corneal diameter, central and minimum corneal thickness, and anterior chamber depth (ACD). The within-subject standard deviation (Sw) and intraclass correlation coefficient (ICC) were calculated. Results: This study comprised 61 eyes of 61 patients ranging in age from 14 to 64 years. For anterior and posterior corneal curvatures and power vector components, the Sw was 0.29 mm or less in all cases. The ICC was above 0.990 in all cases except the flattest curvature of the posterior corneal surface at 3.0 mm, which was 0.840 (moderate agreement), and the posterior power vector J0, which was 0.665 (poor agreement), 0.752, and 0.758 (moderate agreement) for 3.0 mm, 5.0 mm, and 7.0 mm, respectively. In shape factor measurements, the Sw was 0.12 or less in all cases and the ICC ranged between 0.989 and 0.999. Pachymetry, ACD, and WTW had ICC values very close to 1. Conclusion: The new topography system provided repeatable measurements of corneal shape and other anatomic parameters in eyes with keratoconus.
URI: http://hdl.handle.net/10045/39223
ISSN: 0886-3350 (Print) | 1873-4502 (Online)
DOI: 10.1016/j.jcrs.2012.10.033
Idioma: eng
Tipus: info:eu-repo/semantics/article
Drets: © 2012 ASCRS and ESCRS Published by Elsevier Inc.
Revisió científica: si
Versió de l'editor: http://dx.doi.org/10.1016/j.jcrs.2012.10.033
Apareix a la col·lecció: INV - GOPV - Artículos de Revistas