Intrasubject repeatability in keratoconus-eye measurements obtained with a new Scheimpflug photography–based system
Empreu sempre aquest identificador per citar o enllaçar aquest ítem
http://hdl.handle.net/10045/39223
Títol: | Intrasubject repeatability in keratoconus-eye measurements obtained with a new Scheimpflug photography–based system |
---|---|
Autors: | Montalbán, Raúl | Alió, Jorge L. | Javaloy, Jaime | Piñero, David P. |
Grups d'investigació o GITE: | Grupo de Óptica y Percepción Visual (GOPV) |
Centre, Departament o Servei: | Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía |
Paraules clau: | Keratoconus eyes | Intrasubject repeatability | Scheimpflug-photography | Placido-disk technology | Topography system |
Àrees de coneixement: | Óptica |
Data de publicació: | de febrer-2013 |
Editor: | Elsevier |
Citació bibliogràfica: | Journal of Cataract & Refractive Surgery. 2013, 39(2): 211-218. doi:10.1016/j.jcrs.2012.10.033 |
Resum: | Purpose: To evaluate in keratoconus eyes the intrasubject repeatability of anterior and posterior corneal curvature and of other anterior segment anatomic measurements obtained with a new topography system combining Scheimpflug-photography and Placido-disk technology. Setting: Vissum Corporation, Alicante, Spain. Design: Evaluation of technology. Methods: All keratoconus eyes had a comprehensive ophthalmologic examination including analysis with the Sirius system. Three consecutive measurements were obtained to assess the intrasubject repeatability of the following parameters: anterior and posterior corneal curvature and shape factor, white-to-white (WTW) corneal diameter, central and minimum corneal thickness, and anterior chamber depth (ACD). The within-subject standard deviation (Sw) and intraclass correlation coefficient (ICC) were calculated. Results: This study comprised 61 eyes of 61 patients ranging in age from 14 to 64 years. For anterior and posterior corneal curvatures and power vector components, the Sw was 0.29 mm or less in all cases. The ICC was above 0.990 in all cases except the flattest curvature of the posterior corneal surface at 3.0 mm, which was 0.840 (moderate agreement), and the posterior power vector J0, which was 0.665 (poor agreement), 0.752, and 0.758 (moderate agreement) for 3.0 mm, 5.0 mm, and 7.0 mm, respectively. In shape factor measurements, the Sw was 0.12 or less in all cases and the ICC ranged between 0.989 and 0.999. Pachymetry, ACD, and WTW had ICC values very close to 1. Conclusion: The new topography system provided repeatable measurements of corneal shape and other anatomic parameters in eyes with keratoconus. |
URI: | http://hdl.handle.net/10045/39223 |
ISSN: | 0886-3350 (Print) | 1873-4502 (Online) |
DOI: | 10.1016/j.jcrs.2012.10.033 |
Idioma: | eng |
Tipus: | info:eu-repo/semantics/article |
Drets: | © 2012 ASCRS and ESCRS Published by Elsevier Inc. |
Revisió científica: | si |
Versió de l'editor: | http://dx.doi.org/10.1016/j.jcrs.2012.10.033 |
Apareix a la col·lecció: | INV - GOPV - Artículos de Revistas |
Arxius per aquest ítem:
Arxiu | Descripció | Tamany | Format | |
---|---|---|---|---|
2013_Montalban_etal_JCRS_final.pdf | Versión final (acceso restringido) | 108,15 kB | Adobe PDF | Obrir Sol·licitar una còpia |
Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.