Minimum Clearance Distance in Fall Arrest Systems with Energy Absorber Lanyards

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/115327
Información del item - Informació de l'item - Item information
Title: Minimum Clearance Distance in Fall Arrest Systems with Energy Absorber Lanyards
Authors: Carrión Jackson, Elena | Ferrer, Belén | Monge, Juan F. | Saez, Pedro Ignacio | Pomares Torres, Juan Carlos | González Sánchez, Antonio
Research Group/s: Grupo de Ensayo, Simulación y Modelización de Estructuras (GRESMES) | Grupo de Análisis de Imagen, Sistemas Ópticos y Visión (IMAOS+V)
Center, Department or Service: Universidad de Alicante. Departamento de Ingeniería Civil
Keywords: Energy absorber lanyard | Fall arrest systems | Dynamic performance test | Clearance distance | Elastic and plastic deformation | High-speed camera
Knowledge Area: Mecánica de Medios Continuos y Teoría de Estructuras
Issue Date: 28-May-2021
Publisher: MDPI
Citation: Carrión EÁ, Ferrer B, Monge JF, Saez PI, Pomares JC, González A. Minimum Clearance Distance in Fall Arrest Systems with Energy Absorber Lanyards. International Journal of Environmental Research and Public Health. 2021; 18(11):5823. https://doi.org/10.3390/ijerph18115823
Abstract: Accidents due to falls from height are one of the main causes of death in workplaces. Fall arrest systems (FAS) are designed to arrest the fall safely without injuring the accident victim. Their main mission is to restrain the body so as to prevent it from hitting the ground, generating forces and accelerations in the arrest process that are not harmful. A lack of empirical evidence and scant technical information provided by manufacturers regarding minimum clearance distance (MCD) below anchorage makes it necessary to study the safety distances required in the use of Energy Absorber Lanyards (EAL). This paper aims to determine the MCD below anchorage to arrest a fall using an EAL without hitting the ground. The real deformation of EAL when stopping a fall is studied. Ten EAL models distributed internationally by six manufacturers were chosen. Dynamic behavior tests were performed on the samples. Using image processing the total elongation of the equipment (elastic plus plastic) is obtained. The main conclusions are that maximum plastic elongation could be reduced by 29%. The method described in EN 355: 2002 underestimates elongation by up to 70% for some equipment 20% of EAL’s exceed the maximum arrest force (Fm) allowed in EN 355. The MCD data provided by manufacturers is not reliable. The data provided by manufacturers are incomplete. It is recommended that quality control for EAL’s be strengthened to ensure that products launched onto the market meet the requirement of EN355. The findings of this study recommended increasing MCD distance longer than that calculated according to EN355, at less than 1 m.
Sponsor: This research was funded by UNIVERSITY OF ALICANTE and CENTRO DE INNOVACION VERTICAL S.A.C., grant number PC20-01A.
URI: http://hdl.handle.net/10045/115327
ISSN: 1660-4601
DOI: 10.3390/ijerph18115823
Language: eng
Type: info:eu-repo/semantics/article
Rights: © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Peer Review: si
Publisher version: https://doi.org/10.3390/ijerph18115823
Appears in Collections:INV - GRESMES - Artículos de Revistas
INV - IMAOS+V - Artículos de Revistas
INV - BIMAEC - Artículos de Revistas

Files in This Item:
Files in This Item:
File Description SizeFormat 
ThumbnailCarrion_etal_2021_IntJEnvironResPublicHealth.pdf1,25 MBAdobe PDFOpen Preview


Items in RUA are protected by copyright, with all rights reserved, unless otherwise indicated.