Parametric finite element analysis of punching shear behaviour of RC slabs reinforced with bolts

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/99468
Información del item - Informació de l'item - Item information
Título: Parametric finite element analysis of punching shear behaviour of RC slabs reinforced with bolts
Autor/es: Navarro Menargues, Miguel | Ivorra, Salvador | Varona Moya, Francisco de Borja
Grupo/s de investigación o GITE: Grupo de Ensayo, Simulación y Modelización de Estructuras (GRESMES)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Ingeniería Civil
Palabras clave: Finite element analysis | Flat slab | Nonlinearity | Parametric study | Reinforced concrete | Shear bolts | Structural analysis automatization | Structural retrofit
Área/s de conocimiento: Mecánica de Medios Continuos y Teoría de Estructuras
Fecha de publicación: feb-2020
Editor: Elsevier
Cita bibliográfica: Computers & Structures. 2020, 228: 106147. doi:10.1016/j.compstruc.2019.106147
Resumen: Reinforced concrete slabs are an essential part of high-rise structures and are designed to withstand the loads to which they are subjected. However, concrete slabs may fail due to punching shear, which is one of the greatest risks they face. This type of failure, hard to predict, befalls almost instantaneously and may lead to catastrophic consequences. In this paper, ABAQUS is used to analyse a series of non-linear numerical models to simulate the punching shear effect on reinforced bolt-retrofitted concrete flat slabs whose bolts are arranged in three different positions around the support. To start with, an initial calibration of a finite element model was carried out with experimental results reported by Adetifa and Polak. Next, a parametric analysis was performed to determine the influence of the retrofitting geometrical parameters. For this purpose, over two hundred models were created with the help of an automation algorithm programmed in Python. Our parametric study shows that a shear-bolt radial layout may be most adequate for retrofitting slab-to-column connections in which the phenomenon of punching shear is likely to occur. Moreover, the distance between the first pair of bolts and the column’s face is recommended to be approximately five times the diameter of the shear bolts.
URI: http://hdl.handle.net/10045/99468
ISSN: 0045-7949 (Print) | 1879-2243 (Online)
DOI: 10.1016/j.compstruc.2019.106147
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2019 Elsevier Ltd.
Revisión científica: si
Versión del editor: https://doi.org/10.1016/j.compstruc.2019.106147
Aparece en las colecciones:INV - GRESMES - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2020_Navarro_etal_ComputStruct_final.pdfVersión final (acceso restringido)2,44 MBAdobe PDFAbrir    Solicitar una copia
Thumbnail2020_Navarro_etal_ComputStruct_preprint.pdfPreprint (acceso abierto)1,53 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.