Study of influence of ACPA in PVA/AA photopolymer for holographic reflection gratings

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/39983
Información del item - Informació de l'item - Item information
Título: Study of influence of ACPA in PVA/AA photopolymer for holographic reflection gratings
Autor/es: Fernandez-Varo, Helena | Fuentes Rosillo, Rosa | Ortuño, Manuel | Beléndez, Augusto | Pascual, Inmaculada
Grupo/s de investigación o GITE: Holografía y Procesado Óptico
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía | Universidad de Alicante. Departamento de Física, Ingeniería de Sistemas y Teoría de la Señal | Universidad de Alicante. Instituto Universitario de Física Aplicada a las Ciencias y las Tecnologías
Palabras clave: Holography | Holographic recording materials | Photopolymers | Holographic gratings
Área/s de conocimiento: Óptica | Física Aplicada
Fecha de creación: 15-jun-2014
Fecha de publicación: 25-ago-2014
Editor: International Commission for Optics (ICO)
Cita bibliográfica: FERNÁNDEZ VARÓ, Elena, et al. "Study of influence of ACPA in PVA/AA photopolymer for holographic reflection gratings". 23rd Congress of the International Commission for Optics (ICO'23). Santiago de Compostela, 25-29 de agosto de 2014. ISBN 978-84-697-1027-2
Resumen: This work pretends to optimize the standard composition of the PVA/Acrylamide photopolymer, changing its composition in order to improve its spatial resolution. To do this, a chain transfer agent, 4,4'-azobis (4-cyanopentanoic acid) (ACPA) was introduced in the photopolymer and its concentration was modified. Thus, the optimal concentration which gets obtain the maximum diffraction efficiency for high spatial frequencies was found. To quantify the improvement that occurs with the inclusion of the ACPA in the PVA/Acrylamide photopolymer, holographic reflexion gratings of 4553 lines/mm were stored. Moreover, diffraction efficiency obtained with the different concentrations of ACPA was measured to compare the obtained results.
Patrocinador/es: This work was supported by the “Generalitat Valenciana” (Spain) under project PROMETEO/2011/021, ISIC/2012/013 and GV/2012/099 and by “Ministerio de Ciencia e Innovación” (Spain) under projects FIS2011-29803-C02-01 and FIS2011-29803-C02-02.
URI: http://hdl.handle.net/10045/39983
ISBN: 978-84-697-1027-2
Idioma: eng
Tipo: info:eu-repo/semantics/conferenceObject
Revisión científica: si
Aparece en las colecciones:INV - GHPO - Comunicaciones a Congresos, Conferencias, etc.

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailICO-23-Fernandez-2014.pdf596,87 kBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.