Development of a novel pyrolysis-gas chromatography/mass spectrometry method for the analysis of poly(lactic acid) thermal degradation products

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/37892
Registro completo de metadatos
Registro completo de metadatos
Campo DCValorIdioma
dc.contributorAnálisis de Polímeros y Nanomaterialeses
dc.contributor.authorArrieta, Marina Patricia-
dc.contributor.authorParres, Francisco-
dc.contributor.authorLópez, Juan-
dc.contributor.authorJiménez, Alfonso-
dc.contributor.otherUniversidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatologíaes
dc.date.accessioned2014-06-05T11:56:16Z-
dc.date.available2014-06-05T11:56:16Z-
dc.date.issued2013-05-
dc.identifier.citationJournal of Analytical and Applied Pyrolysis. 2013, 101: 150-155. doi:10.1016/j.jaap.2013.01.017es
dc.identifier.issn0165-2370 (Print)-
dc.identifier.issn1873-250X (Online)-
dc.identifier.urihttp://hdl.handle.net/10045/37892-
dc.description.abstractThermal degradation of PLA is a complex process since it comprises many simultaneous reactions. The use of analytical techniques, such as differential scanning calorimetry (DSC) and thermogravimetry (TGA), yields useful information but a more sensitive analytical technique would be necessary to identify and quantify the PLA degradation products. In this work the thermal degradation of PLA at high temperatures was studied by using a pyrolyzer coupled to a gas chromatograph with mass spectrometry detection (Py-GC/MS). Pyrolysis conditions (temperature and time) were optimized in order to obtain an adequate chromatographic separation of the compounds formed during heating. The best resolution of chromatographic peaks was obtained by pyrolyzing the material from room temperature to 600 °C during 0.5 s. These conditions allowed identifying and quantifying the major compounds produced during the PLA thermal degradation in inert atmosphere. The strategy followed to select these operation parameters was by using sequential pyrolysis based on the adaptation of mathematical models. By application of this strategy it was demonstrated that PLA is degraded at high temperatures by following a non-linear behaviour. The application of logistic and Boltzmann models leads to good fittings to the experimental results, despite the Boltzmann model provided the best approach to calculate the time at which 50% of PLA was degraded. In conclusion, the Boltzmann method can be applied as a tool for simulating the PLA thermal degradation.es
dc.description.sponsorshipThis research was supported by the Ministry of Science and Innovation of Spain (MAT2011-28468-C02-02). Marina P. Arrieta thanks Generalitat Valenciana (Spain) for a Santiago Grisolía Grant (GRISOLIA/2011/007).es
dc.languageenges
dc.publisherElsevieres
dc.subjectPoly(lactic acid)es
dc.subjectThermal degradationes
dc.subjectPyrolysises
dc.subjectPy-GC/MSes
dc.subjectLogistic modeles
dc.subjectBoltzmann modeles
dc.subject.otherQuímica Analíticaes
dc.titleDevelopment of a novel pyrolysis-gas chromatography/mass spectrometry method for the analysis of poly(lactic acid) thermal degradation productses
dc.typeinfo:eu-repo/semantics/articlees
dc.peerreviewedsies
dc.identifier.doi10.1016/j.jaap.2013.01.017-
dc.relation.publisherversionhttp://dx.doi.org/10.1016/j.jaap.2013.01.017es
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses
dc.relation.projectIDinfo:eu-repo/grantAgreement/MICINN//MAT-2011-28468-C02-02-
Aparece en las colecciones:INV - NANOBIOPOL - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2013_Arrieta_etal_JAAP_final.pdfVersión final (acceso restringido)620,95 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.