Clinical Evaluation of a New Spectral-Domain Optical Coherence Tomography-Based Biometer

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/141313
Información del item - Informació de l'item - Item information
Título: Clinical Evaluation of a New Spectral-Domain Optical Coherence Tomography-Based Biometer
Autor/es: Alió, Jorge L. | José-Martínez, Marina | Martínez-Abad, Antonio | Rodríguez, Alejandra E. | Versaci, Francesco | Hjortdal, Jesper | Murta, Joaquim Neto | Plaza Puche, Ana B. | Cantó-Cerdán, Mario | Piñero, David P.
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Optical biometry | Axial length | Anterior chamber depth | Central corneal thickness | Swept source optical coherence tomography | Spectral-domain optical coherence tomograph
Fecha de publicación: 6-mar-2024
Editor: MDPI
Cita bibliográfica: Diagnostics. 2024, 14(5): 560. https://doi.org/10.3390/diagnostics14050560
Resumen: The VEMoS-AXL system is a new optical biometer based on spectral domain optical coherence tomography (SD-OCT) that has been tested in terms of intrasession repeatability and compared with a swept-source optical coherence tomography biometer (SS-OCT), which is recognized as the gold standard for the performance of an agreement analysis. A biometric analysis was performed three consecutive times in 120 healthy eyes of 120 patients aged between 18 and 40 years with the SD-OCT system, and afterwards, a single measurement was obtained with the SS-OCT system. Within-subject standard deviations were 0.004 mm, 4.394 µm, and 0.017 mm for axial length (AL), central corneal thickness (CCT), and anterior chamber depth (ACD) measures obtained with the SD-OCT biometer, respectively. The agreement between devices was good for AL (limits of agreement, LoA: −0.04 to 0.03 mm) and CCT (LoA: −4.36 to 14.38 µm), whereas differences between devices were clinically relevant for ACD (LoA: 0.03 to 0.21 mm). In conclusion, the VEMoS-AXL system provides consistent measures of anatomical parameters, being most of them interchangeable with those provided by the SS-OCT-based gold standard.
Patrocinador/es: The results with the device VEMoS-AXL are part of a project that has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 878748.
URI: http://hdl.handle.net/10045/141313
ISSN: 2075-4418
DOI: 10.3390/diagnostics14050560
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Revisión científica: si
Versión del editor: https://doi.org/10.3390/diagnostics14050560
Aparece en las colecciones:Investigaciones financiadas por la UE
INV - GOPV - Artículos de Revistas