Misalignment error analysis in polychromatic division of focal plane Stokes polarimeters

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/92347
Información del item - Informació de l'item - Item information
Title: Misalignment error analysis in polychromatic division of focal plane Stokes polarimeters
Authors: Lizana Tutusaus, Ángel | Campos Coloma, Juan | Van Eeckhout, Albert | Márquez, Andrés
Research Group/s: Holografía y Procesado Óptico
Center, Department or Service: Universidad de Alicante. Departamento de Física, Ingeniería de Sistemas y Teoría de la Señal
Keywords: Image sensors | Polarimetric imaging | Polarized light
Knowledge Area: Física Aplicada
Issue Date: 15-May-2019
Publisher: Optical Society of America
Citation: Angel Lizana, Juan Campos, Albert Van Eeckhout, and Andrés Marquez, "Misalignment error analysis in polychromatic division of focal plane Stokes polarimeters," OSA Continuum 2, 1565-1575 (2019). doi:10.1364/OSAC.2.001565
Abstract: Snapshot imaging polarimeters are used in many different areas. Recently, division of focal plane (DoFP) polarimeters have proved useful as snapshot polarimeters for dynamic applications. For an optimal performance of polarimeters, different works dealing with the error analysis of such devices are proposed in literature. In terms of noise amplification from intensity measurements to the final polarization calculations, well-established quality metrics, as in the condition number or the equally weighted variance criteria, are used. Other studies analyze systematic errors due to deviations in the construction parameters. However, something not considered so far is the effect produced by misalignment between the various pixelated masks over the pixelated structure of the camera sensor, always occurring in experimental implementations of DoFPs. In this work, we study the effect of such misalignments in DoFP polarimeters and demonstrate how they lead to polarimetric systems composed of partially depolarized analyzers. We calculate the combined degree of polarization related to different amounts of misalignment and analyze the corresponding system performance. From this study, we show how an imaging polarimeter based on partially polarized analyzers can still lead to a robust and accurate polarimetric performance, and we also provide the misalignment limits in which an acceptable performance is obtained. We evaluate both the monochromatic and the polychromatic cases with special focus on the latter.
Sponsor: Ministerio de Economía y Competitividad (MINECO) (FIS2015-66328-C3-1-R, fondos FEDER).
URI: http://hdl.handle.net/10045/92347
ISSN: 2578-7519
DOI: 10.1364/OSAC.2.001565
Language: eng
Type: info:eu-repo/semantics/article
Rights: © 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement. Authors and readers may use, reuse, and build upon the article, or use it for text or data mining without asking prior permission from the publisher or the Author(s), as long as the purpose is non-commercial and appropriate attribution is maintained.
Peer Review: si
Publisher version: https://doi.org/10.1364/OSAC.2.001565
Appears in Collections:INV - GHPO - Artículos de Revistas

Files in This Item:
Files in This Item:
File Description SizeFormat 
Thumbnail2019_Lizana_etal_OSAContinuum.pdf1,49 MBAdobe PDFOpen Preview


Items in RUA are protected by copyright, with all rights reserved, unless otherwise indicated.