Temporal evolution of the angular response of a holographic diffraction grating in PVA/acrylamide photopolymer

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/9111
Registro completo de metadatos
Registro completo de metadatos
Campo DCValorIdioma
dc.contributorHolografía y Procesado Ópticoen
dc.contributor.authorGallego, Sergi-
dc.contributor.authorOrtuño, Manuel-
dc.contributor.authorNeipp, Cristian-
dc.contributor.authorGarcía Llopis, Celia-
dc.contributor.authorBeléndez, Augusto-
dc.contributor.authorPascual, Inmaculada-
dc.contributor.otherUniversidad de Alicante. Departamento de Física, Ingeniería de Sistemas y Teoría de la Señalen
dc.contributor.otherUniversidad de Alicante. Departamento de Óptica, Farmacología y Anatomíaen
dc.date.accessioned2009-01-21T10:55:00Z-
dc.date.available2009-01-21T10:55:00Z-
dc.date.created2002-
dc.date.issued2003-01-27-
dc.identifier.citationGALLEGO RICO, Sergi, et al. "Temporal evolution of the angular response of a holographic diffraction grating in PVA/acrylamide photopolymer". Optics Express Vol. 11, No. 2 (2003). ISSN 1094-4087, pp. 181-190en
dc.identifier.issn1094-4087-
dc.identifier.urihttp://hdl.handle.net/10045/9111-
dc.description.abstractIn this paper we evaluate the temporal evolution, after exposure, of a diffraction grating stored in a PVA/acrylamide photopolymer. We also study the overmodulation of the refractive index inside the hologram, which gives rise to a particular behaviour of the angular response of diffraction efficiency. This evolution takes place in our photopolymer due to theincorporation of dimethylacrylamide (DMAA), which is a liquid at room temperature and so favours diffusion of the species in solution from the zones of greater concentration to those of lower concentration.en
dc.description.sponsorshipThis work was supported by the “Ministerio de Ciencia y Tecnología” (CICYT, Spain) under project MAT2000-1361-C04-04 and by the “Oficina de Ciencia y Tecnología” (Generalitat Valenciana, Spain) under project GV01-130.en
dc.languageengen
dc.publisherOptical Society of Americaen
dc.rightsThis paper was published in Optics Express and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-11-2-181. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law.en
dc.subjectHolographyen
dc.subjectVolume holographic gratingsen
dc.subjectHolographic recording materialsen
dc.subjectPolymersen
dc.subject.otherÓpticaen
dc.subject.otherFísica Aplicadaen
dc.titleTemporal evolution of the angular response of a holographic diffraction grating in PVA/acrylamide photopolymeren
dc.typeinfo:eu-repo/semantics/articleen
dc.peerreviewedsien
dc.identifier.doi10.1364/OE.11.000181-
dc.relation.publisherversionhttp://dx.doi.org/10.1364/OE.11.000181-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Aparece en las colecciones:INV - GHPO - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailOEx_v11_n2_p188_2003.pdf680 kBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.