Determination of aflatoxin M1 in milk samples by means of an inductively coupled plasma mass spectrometry-based immunoassay
Empreu sempre aquest identificador per citar o enllaçar aquest ítem
http://hdl.handle.net/10045/64988
Títol: | Determination of aflatoxin M1 in milk samples by means of an inductively coupled plasma mass spectrometry-based immunoassay |
---|---|
Autors: | Pérez Hernández, Emma | Martínez-Peinado, Pascual | Marco, Francisco M. | Gras, Luis | Sempere Ortells, José Miguel | Mora, Juan | Grindlay, Guillermo |
Grups d'investigació o GITE: | Espectrometría Atómica Analítica (GEAA) | Grupo de Inmunología, Biología Celular y del Desarrollo |
Centre, Departament o Servei: | Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología | Universidad de Alicante. Departamento de Biotecnología |
Paraules clau: | Aflatoxin M1 | Milk | Immunoassay | Gold nanoparticles | Inductively coupled plasma mass spectrometry |
Àrees de coneixement: | Química Analítica | Inmunología |
Data de publicació: | 1-de setembre-2017 |
Editor: | Elsevier |
Citació bibliogràfica: | Food Chemistry. 2017, 230: 721-727. doi:10.1016/j.foodchem.2017.03.078 |
Resum: | An inductively coupled plasma mass spectrometry (ICP-MS)-based immunoassay has been developed to quantify aflatoxin M1 (AFM1) at ultra-trace levels in milk samples. AFM1 detection is carried out by means of a competitive immunoassay using secondary biotinylated antibodies and streptavidin-conjugated Au nanoparticles. After acid addition, nanoparticles are decomposed and Au signal is registered by means of ICP-MS. Results demonstrate that, under optimum conditions, the limit of detection of the immunoassay (0.005 μg kg−1) is low enough to quantify AFM1 according to current international policies (including the more restrictive European one). Method accuracy and precision was checked by analyzing an AFM1 certified reference material and different milk samples spiked with known amounts of AFM1. AFM1 recovery values range from 80% to 102% whereas inter-assay and intra-assay precision are lower than 15%. Finally, this immunoassay methodology affords a higher dynamic working range (0.012–2.5 μg kg−1) than other immunoassay methodologies described in the literature. |
Patrocinadors: | The authors would like to thank the Generalitat Valenciana (Project GV/2014/138) and the Vice-Presidency for Research of the University of Alicante – Spain (Project GRE12-19) for the financial support of this work. E. Pérez also thanks the University of Alicante – Spain for the fellowship (UAFPU2011). |
URI: | http://hdl.handle.net/10045/64988 |
ISSN: | 0308-8146 (Print) | 1873-7072 (Online) |
DOI: | 10.1016/j.foodchem.2017.03.078 |
Idioma: | eng |
Tipus: | info:eu-repo/semantics/article |
Drets: | © 2017 Elsevier Ltd. |
Revisió científica: | si |
Versió de l'editor: | http://dx.doi.org/10.1016/j.foodchem.2017.03.078 |
Apareix a la col·lecció: | INV - Grupo de Inmunología - Artículos de Revistas INV - GEAA - Artículos de Revistas |
Arxius per aquest ítem:
Arxiu | Descripció | Tamany | Format | |
---|---|---|---|---|
2017_Perez_etal_FoodChem_final.pdf | Versión final (acceso restringido) | 603,99 kB | Adobe PDF | Obrir Sol·licitar una còpia |
2017_Perez_etal_FoodChem_accepted.pdf | Accepted Manuscript (acceso abierto) | 640,83 kB | Adobe PDF | Obrir Vista prèvia |
Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.