The influence of the sample introduction system on signals of different tin compounds in inductively coupled plasma-based techniques

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/38777
Información del item - Informació de l'item - Item information
Título: The influence of the sample introduction system on signals of different tin compounds in inductively coupled plasma-based techniques
Autor/es: Montiel Bonmatí, Javier | Grindlay, Guillermo | Gras, Luis | Loos-Vollebregt, Margaretha T.C. de | Mora, Juan
Grupo/s de investigación o GITE: Espectrometría Atómica Analítica
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología
Palabras clave: Tin compounds | Nebulizer | Spray chamber | ICP-AES | ICP-MS
Área/s de conocimiento: Química Analítica
Fecha de publicación: 1-mar-2013
Editor: Elsevier
Cita bibliográfica: Spectrochimica Acta Part B: Atomic Spectroscopy. 2013, 81: 36-42. doi:10.1016/j.sab.2012.12.008
Resumen: The influence of the sample introduction system on the signals obtained with different tin compounds in inductively coupled plasma (ICP) based techniques, i.e., ICP atomic emission spectrometry (ICP–AES) and ICP mass spectrometry (ICP–MS) has been studied. Signals for test solutions prepared from four different tin compounds (i.e., tin tetrachloride, monobutyltin, dibutyltin and di-tert-butyltin) in different solvents (methanol 0.8% (w/w), i-propanol 0.8% (w/w) and various acid matrices) have been measured by ICP–AES and ICP–MS. The results demonstrate a noticeable influence of the volatility of the tin compounds on their signals measured with both techniques. Thus, in agreement with the compound volatility, the highest signals are obtained for tin tetrachloride followed by di-tert-butyltin/monobutyltin and dibutyltin. The sample introduction system exerts an important effect on the amount of solution loading the plasma and, hence, on the relative signals afforded by the tin compounds in ICP–based techniques. Thus, when working with a pneumatic concentric nebulizer, the use of spray chambers affording high solvent transport efficiency to the plasma (such as cyclonic and single pass) or high spray chamber temperatures is recommended to minimize the influence of the tin chemical compound. Nevertheless, even when using the conventional pneumatic nebulizer coupled to the best spray chamber design (i.e., a single pass spray chamber), signals obtained for di-tert-butyltin/monobutyltin and dibutyltin are still around 10% and 30% lower than the corresponding signal for tin tetrachloride, respectively. When operating with a pneumatic microconcentric nebulizer coupled to a 50 °C-thermostated cinnabar spray chamber, all studied organotin compounds provided similar emission signals although about 60% lower than those obtained for tin tetrachloride. The use of an ultrasonic nebulizer coupled to a desolvation device provides the largest differences in the emission signals, among all tested systems.
URI: http://hdl.handle.net/10045/38777
ISSN: 0584-8547 (Print) | 1873-3565 (Online)
DOI: 10.1016/j.sab.2012.12.008
Idioma: eng
Tipo: info:eu-repo/semantics/article
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1016/j.sab.2012.12.008
Aparece en las colecciones:INV - GEAA - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2013_Montiel_etal_SAPB_final.pdfVersión final (acceso restringido)565,49 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.