Concurrent Validity of the Ergotex Device for Measuring Low Back Posture

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/139915
Información del item - Informació de l'item - Item information
Título: Concurrent Validity of the Ergotex Device for Measuring Low Back Posture
Autor/es: García-Luna, Marco A. | Jimenez-Olmedo, Jose Manuel | Pueo, Basilio | Manchado, Carmen | Cortell-Tormo, Juan M.
Grupo/s de investigación o GITE: Salud, Actividad Física y Tecnología Deportiva (HEALTH-TECH) | Grupo de Investigación en Entrenamiento Deportivo y Rendimiento (SCAPE)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Didáctica General y Didácticas Específicas
Palabras clave: Kinematics | IMU | Wearable | Instrumentation | Posture
Fecha de publicación: 20-ene-2024
Editor: MDPI
Cita bibliográfica: García-Luna MA, Jimenez-Olmedo JM, Pueo B, Manchado C, Cortell-Tormo JM. Concurrent Validity of the Ergotex Device for Measuring Low Back Posture. Bioengineering. 2024; 11(1):98. https://doi.org/10.3390/bioengineering11010098
Resumen: Highlighting the crucial role of monitoring and quantifying lumbopelvic rhythm for spinal curvature, the Ergotex IMU, a portable, lightweight, cost-effective, and energy-efficient technology, has been specifically designed for the pelvic and lumbar area. This study investigates the concurrent validity of the Ergotex device in measuring sagittal pelvic tilt angle. We utilized an observational, repeated measures design with healthy adult males (mean age: 39.3 ± 7.6 y, body mass: 82.2 ± 13.0 kg, body height: 179 ± 8 cm), comparing Ergotex with a 3D optical tracking system. Participants performed pelvic tilt movements in anterior, neutral, and posterior conditions. Statistical analysis included paired samples t-tests, Bland–Altman plots, and regression analysis. The findings show minimal systematic error (0.08° overall) and high agreement between the Ergotex and optical tracking, with most data points falling within limits of agreement of Bland–Altman plots (around ±2°). Significant differences were observed only in the anterior condition (0.35°, p < 0.05), with trivial effect sizes (ES = 0.08), indicating that these differences may not be clinically meaningful. The high Pearson’s correlation coefficients across conditions underscore a robust linear relationship between devices (r > 0.9 for all conditions). Regression analysis showed a standard error of estimate (SEE) of 1.1° with small effect (standardized SEE < 0.26 for all conditions), meaning that the expected average deviation from the true value is around 1°. These findings validate the Ergotex as an effective, portable, and cost-efficient tool for assessing sagittal pelvic tilt, with practical implications in clinical and sports settings where traditional methods might be impractical or costly.
Patrocinador/es: This research was funded by the Ministry of Universities of Spain (grant number FPU20/01843) and by the Valencian Innovation Agency of Spain (grant number INNVA1/2020/81).
URI: http://hdl.handle.net/10045/139915
ISSN: 2306-5354
DOI: 10.3390/bioengineering11010098
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Revisión científica: si
Versión del editor: https://doi.org/10.3390/bioengineering11010098
Aparece en las colecciones:INV - HEALTH-TECH - Artículos de Revistas
INV - SCAPE - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailGarcia-Luna_etal_2024_Bioengineering.pdf1,06 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.