Intrasession repeatability of corneal, limbal and scleral measurements obtained with a fourier transform profilometer

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/115180
Registre complet
Registre complet
Camp Dublin Core Valor Idioma
dc.contributorGrupo de Óptica y Percepción Visual (GOPV)es_ES
dc.contributor.authorBataille, Laurent-
dc.contributor.authorMolina-Martín, Ainhoa-
dc.contributor.authorPiñero, David P.-
dc.contributor.otherUniversidad de Alicante. Departamento de Óptica, Farmacología y Anatomíaes_ES
dc.date.accessioned2021-05-20T14:21:21Z-
dc.date.available2021-05-20T14:21:21Z-
dc.date.issued2020-11-23-
dc.identifier.citationContact Lens and Anterior Eye. 2021, 44(5): 101382. https://doi.org/10.1016/j.clae.2020.11.002es_ES
dc.identifier.issn1367-0484 (Print)-
dc.identifier.issn1476-5411 (Online)-
dc.identifier.urihttp://hdl.handle.net/10045/115180-
dc.description.abstractPurpose: To evaluate the intrasession repeatability of corneal, limbal and scleral measurements obtained by an experienced operator with a Fourier transform profilometer in healthy eyes. Methods: Prospective, single-center study including 35 eyes of 35 participants with ages ranging from 13 to 52 years. All patients underwent three consecutive corneoscleral topographic evaluations with the Eye Surface Profiler (ESP) system (Eaglet Eye b.v.). Intrasession repeatability was analyzed for different geometric and sagittal height variables using the following parameters: the within-subject standard deviation (Sw) of the three consecutive measurements, intrasubject precision (1.96 × Sw), coefficient of variation (CV) and the intraclass correlation coefficient (ICC). Results: Inner best fit sphere (BFS) showed good repeatability, with ICC of 0.844. Higher variability was observed for the repeated measurements of limbus and outer BFS, with ICCs of 0.636 and 0.739, respectively. For mean corneal and scleral radius, ICCs were 0.933 and 0.888, respectively. The repeatability of all sagittal height data was good for all chords evaluated (11–15 mm), with Sw values from 0.02 to 0.11 mm, and ICCs from 0.568 to 0.909. A significant positive correlation was found between the magnitude of temporal-nasal sagittal height difference for all measured chords and its Sw associated. Conclusion: The ESP system can provide consistent measurements of sagittal height data for different chord diameters as well as for mean corneal and scleral radius in healthy eyes. Best fit approaches for limbal and scleral areas were less repeatable, although within a clinically acceptable range.es_ES
dc.description.sponsorshipThis article is funded by the Project UAIND18−06B of the University of Alicante within the program “Ayudas destinadas a la formación predoctoral en colaboración con empresas 2018″ supported by the Vicerrectorado de Investigación y Transferencia de Conocimiento. The author David P Piñero has been also supported by the Ministry of Economy, Industry and Competitiveness of Spain within the program Ramón y Cajal, RYC-2016-20471.es_ES
dc.languageenges_ES
dc.publisherElsevieres_ES
dc.rights© 2020 British Contact Lens Association. Published by Elsevier Ltd.es_ES
dc.subjectCorneo-scleral topographyes_ES
dc.subjectEye surface profileres_ES
dc.subjectProfilometryes_ES
dc.subjectOcular sagittal heightes_ES
dc.subjectRepeatabilityes_ES
dc.subjectConjunctivaes_ES
dc.subject.otherÓpticaes_ES
dc.titleIntrasession repeatability of corneal, limbal and scleral measurements obtained with a fourier transform profilometeres_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.peerreviewedsies_ES
dc.identifier.doi10.1016/j.clae.2020.11.002-
dc.relation.publisherversionhttps://doi.org/10.1016/j.clae.2020.11.002es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/MINECO//RYC-2016-20471-
Apareix a la col·lecció: INV - GOPV - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
ThumbnailBataille_etal_2020_ContactLensAnteriorEye_final.pdfVersión final (acceso restringido)333,88 kBAdobe PDFObrir     Sol·licitar una còpia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.