Influence of temporal averaging in the performance of a rotating retarder imaging Stokes polarimeter

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/110369
Información del item - Informació de l'item - Item information
Título: Influence of temporal averaging in the performance of a rotating retarder imaging Stokes polarimeter
Autor/es: Lizana Tutusaus, Ángel | Campos Coloma, Juan | Van Eeckhout, Albert | Márquez, Andrés
Grupo/s de investigación o GITE: Holografía y Procesado Óptico
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Física, Ingeniería de Sistemas y Teoría de la Señal | Universidad de Alicante. Instituto Universitario de Física Aplicada a las Ciencias y las Tecnologías
Palabras clave: Rotating retarder fixed polarizer | Temporal averaging | Stokes polarimeter
Área/s de conocimiento: Física Aplicada
Fecha de publicación: 13-abr-2020
Editor: Optical Society of America
Cita bibliográfica: Ángel Lizana, Juan Campos, Albert Van Eeckhout, and Andrés Márquez, "Influence of temporal averaging in the performance of a rotating retarder imaging Stokes polarimeter," Opt. Express 28, 10981-11000 (2020). https://doi.org/10.1364/OE.385623
Resumen: We study the optimum operating conditions for a rotating retarder fixed polarizer (RRFP) when the measurements are not quasi-instantaneous but time-averaged. We obtain the optimum retardance and retarder orientations as a function of the integrated angle interval. We also study how the increase in the number of time-averaged measurements leads to a better equally weighted variance (EWV) value, and thus, to a better performance of the polarimeter in terms of noise amplification for the case of additive noise. Two different analyzers configurations are studied in this work: uniformly spaced retarder angles and when measurements are taken at optimum angles (non-uniformly spaced angles). We also consider the case of polychromatic illumination. We discuss the best measurement conditions in terms of the signal-to-noise ratio depending on whether there is a fixed or a limited amount of photons per measurement.
Patrocinador/es: Ministerio de Economía y Competitividad (Fondos Feder, RTI2018-097107-B-C31); Agència de Gestió d’Ajuts Universitaris i de Recerca (SGR 2017-00150).
URI: http://hdl.handle.net/10045/110369
ISSN: 1094-4087
DOI: 10.1364/OE.385623
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
Revisión científica: si
Versión del editor: https://doi.org/10.1364/OE.385623
Aparece en las colecciones:INV - GHPO - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailLizana_etal_2020_OptExpress.pdf1,85 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.