A new matrix formulation of spectacle magnification using pupil magnification. II and III: High myopia corrected with contact lenses and intraocular lenses

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/9290
Información del item - Informació de l'item - Item information
Título: A new matrix formulation of spectacle magnification using pupil magnification. II and III: High myopia corrected with contact lenses and intraocular lenses
Autor/es: García, Mónica | González Pérez, Concepción | Pascual, Inmaculada
Grupo/s de investigación o GITE: Holografía y Procesado Óptico
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Intraocular lenses | High myopia | Matrix formulation
Área/s de conocimiento: Óptica | Oftalmología
Fecha de creación: 13-oct-1995
Fecha de publicación: nov-1996
Editor: The College of Optometrists | Elsevier
Cita bibliográfica: GARCÍA, Mónica; GONZÁLEZ PÉREZ, Concepción; PASCUAL VILLALOBOS, Inmaculada. "A new matrix formulation of spectacle magnification using pupil magnification. II and III: High myopia corrected with contact lenses and intraocular lenses". Ophthalmic and Physiological Optics. Vol. 16, No. 6 (November 1996). ISSN 0275-5408, pp. 498-506
Resumen: In this paper we use the matrix method to calculate spectacle magnification (SM) and relative spectacle magnification (RSM) using pupil magnification for myopic eyes corrected with contact lenses (CLs), and intraocular lenses (IOLs). For myopic eyes corrected with contact lenses, the calculation is very similar to the one done for myopic eyes corrected with ophthalmic lenses (OLs) since both OLs and CLs are external correcting systems. For myopic eyes corrected with intraocular lenses, the calculation is different from the ones carried out for myopic eyes with external correcting systems. In this paper we show the differences that exist between the matrix calculations for these two correcting systems, external and internal. The magnifications are calculated for specific myopic eyes corrected with CLs and IOLs. By comparing the results obtained with three correction types, namely, OLs, CLs and IOLs, we will be able to choose the best correction system for each case.
URI: http://hdl.handle.net/10045/9290
ISSN: 0275-5408 (Print) | 1475-1313 (Online)
DOI: 10.1046/j.1475-1313.1996.96000142.x
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: The definitive version is available at www.blackwell-synergy.com
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1046/j.1475-1313.1996.96000142.x
Aparece en las colecciones:INV - GHPO - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailOPO_v16_n6_p498_1996.pdfVersión final (acceso restringido)621,74 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.