New theoretical matrix formula for intraocular lens calculation using the optimal bending factor

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/9270
Registro completo de metadatos
Registro completo de metadatos
Campo DCValorIdioma
dc.contributorHolografía y Procesado Ópticoen
dc.contributor.authorFimia Gil, Antonio-
dc.contributor.authorAlió y Sanz, Jorge L.-
dc.contributor.authorPascual, Inmaculada-
dc.contributor.authorBeléndez, Augusto-
dc.contributor.otherUniversidad de Alicante. Departamento de Óptica, Farmacología y Anatomíaen
dc.contributor.otherUniversidad de Alicante. Departamento de Física, Ingeniería de Sistemas y Teoría de la Señalen
dc.date.accessioned2009-01-29T11:52:47Z-
dc.date.available2009-01-29T11:52:47Z-
dc.date.created1992-
dc.date.issued1993-03-
dc.identifier.citationFIMIA GIL, Antonio, et al. "New theoretical matrix formula for intraocular lens calculation using the optimal bending factor". Journal of Cataract & Refractive Surgery. Vol. 19 (March 1993). ISSN 0886-3350, pp. 293-297en
dc.identifier.issn0886-3350 (Print)-
dc.identifier.issn1873-4502 (Online)-
dc.identifier.urihttp://hdl.handle.net/10045/9270-
dc.description.abstractBy applying Gaussian optics we propose a new matrix formula model for intraocular lens (IOL) calculation that yields not only IOL optical power for a particular eye but also an evaluation of the bending factor of different IOL optical designs. This option improves IOL selection and results in the best possible optical image, a function dependent on the IOL's bending factor. This formula is a new approach to IOL calculation and may be useful in designing IOLs for abnormally hyperopic or myopic eyes. Optimal IOL power and design should both be considered in IOL calculation, which may improve the optical and clinical results of IOL implantation in the aphakic patient. The radius of the cornea is assumed to be spherical, and aspherical curves of the cornea may influence the optimal "bending" or shape factor of a lens.en
dc.languageengen
dc.publisherAmerican Society of Cataract and Refractive Surgeryen
dc.publisherEuropean Society of Cataract and Refractive Surgeonsen
dc.publisherElsevieren
dc.subjectAphakiaen
dc.subjectBending factoren
dc.subjectIntraocular lensen
dc.subjectOptical aberrationen
dc.subjectOptical poweren
dc.subjectMatrix calculationen
dc.subjectRetinal imageen
dc.subject.otherÓpticaen
dc.titleNew theoretical matrix formula for intraocular lens calculation using the optimal bending factoren
dc.typeinfo:eu-repo/semantics/articleen
dc.peerreviewedsien
dc.identifier.doi10.1016/S0886-3350(13)80959-5-
dc.relation.publisherversionhttp://dx.doi.org/10.1016/S0886-3350(13)80959-5-
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccess-
Aparece en las colecciones:INV - GHPO - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailJCRS_v19_n2_p293_1993.pdfVersión final (acceso restringido)913,66 kBAdobe PDFAbrir    Solicitar una copia
ThumbnailJCRS_v19_n2_p293_1993pre.pdfVersión revisada (acceso libre)1,05 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.