Intra-session repeatability of iridocorneal angle measurements provided by a Scheimpflug photography-based system in healthy eyes

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/63307
Información del item - Informació de l'item - Item information
Título: Intra-session repeatability of iridocorneal angle measurements provided by a Scheimpflug photography-based system in healthy eyes
Autor/es: Ruiz-Belda, Clara | Piñero, David P. | Ruiz Fortes, Pedro | Soto-Negro, Roberto | Moya, Myriam | Pérez Cambrodí, Rafael J. | Artola, Alberto
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Iridocorneal angle | Scheimpflug imaging | Sirius | Anterior chamber angle
Área/s de conocimiento: Óptica
Fecha de publicación: ene-2016
Editor: Springer Berlin Heidelberg
Cita bibliográfica: Graefe's Archive for Clinical and Experimental Ophthalmology. 2016, 254(1): 169-175. doi:10.1007/s00417-015-3105-0
Resumen: Purpose: The purpose of this study was to evaluate intra-session repeatability of measurements of the iridocorneal angle at different meridians in the nasal and temporal areas in healthy eyes using the Sirius Scheimpflug photography-based system in glaucoma analysis mode. Methods: A total of 43 eyes of 43 patients ranging in age from 36 to 79 years were enrolled in the study. All eyes received a comprehensive ophthalmologic examination including a complete anterior segment analysis with the Costruzione Strumenti Oftalmici [CSO] Sirius system. Three consecutive measurements of nasal and temporal angles at 0°, ±10°, ±20°, and ±30° meridians were obtained in order to assess the intra-session repeatability of iridocorneal angle measurements provided by the device using the glaucoma analysis mode. Within-subject standard deviation (Sw), coefficient of variation (CV), and intraclass correlation coefficient (ICC) values were calculated. Results: The mean Sw was 1.07 ± 1.09°, 1.22 ± 1.53°, 0.66 ± 0.51°, 0.86 ± 0.57°, 0.68 ± 0.65°, 0.84 ± 0.68°, and 0.91 ± 0.70° at the temporal 30°, 20°, 10°, 0°, −10°, −20°, and −30° positions, respectively. Mean Sw was 3.13 ± 3.15°, 3.43 ± 3.63°, 2.75 ± 2.29°, 2.19 ± 1.55°, 1.90 ± 1.49°, 2.14 ± 1.74°, and 2.24 ± 2.06° at the temporal −30°, −20°, −10°, 0°, 10°, 20°, and 30° positions, respectively. Mean CV ranged from 1.36 ± 1.05 % (nasal 0° position) to 10.92 ± 13.95 % (nasal −20° position). ICC values ranged from 0.778 to 0.972. Conclusions: The glaucoma analysis mode of the Sirius system provides consistent measurements of the iridocorneal angle at different meridians in healthy eyes, with slightly less consistency for nasal measurements. It may be considered a clinically useful non-invasive technique for the detection of potentially occludable angles.
URI: http://hdl.handle.net/10045/63307
ISSN: 0721-832X (Print) | 1435-702X (Online)
DOI: 10.1007/s00417-015-3105-0
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © Springer-Verlag Berlin Heidelberg 2015. The final publication is available at Springer via http://dx.doi.org/10.1007/s00417-015-3105-0
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1007/s00417-015-3105-0
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2016_Ruiz-Belda_etal_Graefes_final.pdfVersión final (acceso restringido)491,52 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.