Peristrophic multiplexed holograms recorded in a low toxicity photopolymer

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/60807
Registro completo de metadatos
Registro completo de metadatos
Campo DCValorIdioma
dc.contributorHolografía y Procesado Ópticoes_ES
dc.contributor.authorNavarro-Fuster, Víctor-
dc.contributor.authorOrtuño, Manuel-
dc.contributor.authorFernandez, Roberto-
dc.contributor.authorGallego, Sergi-
dc.contributor.authorMárquez, Andrés-
dc.contributor.authorBeléndez, Augusto-
dc.contributor.authorPascual, Inmaculada-
dc.contributor.otherUniversidad de Alicante. Departamento de Óptica, Farmacología y Anatomíaes_ES
dc.contributor.otherUniversidad de Alicante. Departamento de Física, Ingeniería de Sistemas y Teoría de la Señales_ES
dc.contributor.otherUniversidad de Alicante. Instituto Universitario de Física Aplicada a las Ciencias y las Tecnologíases_ES
dc.date.accessioned2016-12-14T07:56:49Z-
dc.date.available2016-12-14T07:56:49Z-
dc.date.created2016-10-11-
dc.date.issued2017-01-01-
dc.identifier.citationV. Navarro-Fuster, M. Ortuño, R. Fernández, S. Gallego, A. Márquez, A. Beléndez, I. Pascual, "Peristrophic multiplexed holograms recorded in a low toxicity photopolymer," Opt. Mater. Express 7, 133-147 (2017). doi:10.1364/OME.7.000133es_ES
dc.identifier.issn2159-3930-
dc.identifier.urihttp://hdl.handle.net/10045/60807-
dc.description.abstractMultiplexed diffraction gratings were recorded in 300 μm thick layers of biophotopol photopolymer by using two peristrophic multiplexing schemes separately and in combination. In addition, it was shown that riboflavin may be used as polymer initiator in acrylamide photopolymer films and the holographic properties of these films such as diffraction efficiency and dynamic range were compared with those of the biophotopol photopolymer. A variable exposure scheduling method was adopted to store the gratings using a 488 nm Ar laser. Thirteen nearly uniform sinusoidal wave gratings could be recorded in a low toxicity recording medium with a variable exposure energy scheduling method. The diffraction efficiency and dynamic range obtained using the two multiplexing schemes were compared.es_ES
dc.description.sponsorshipMinisterio de Economía y Competitividad (Spain) (FIS2014-56100-C2-1-P and FIS2015-66570-P); Generalitat Valenciana (Spain) (PROMETEO II/2015/015).es_ES
dc.languageenges_ES
dc.publisherOptical Society of Americaes_ES
dc.rightsThis paper was published in Optical Materials Express and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: https://www.osapublishing.org/ome/abstract.cfm?uri=ome-7-1-133. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law.es_ES
dc.subjectHolographyes_ES
dc.subjectHolographic recording materialses_ES
dc.subjectMultiplex holographyes_ES
dc.subjectOptical storage-recording materialses_ES
dc.subjectOptical materialses_ES
dc.subjectBiomaterialses_ES
dc.subject.otherÓpticaes_ES
dc.subject.otherFísica Aplicadaes_ES
dc.titlePeristrophic multiplexed holograms recorded in a low toxicity photopolymeres_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.peerreviewedsies_ES
dc.identifier.doi10.1364/OME.7.000133-
dc.relation.publisherversionhttps://doi.org/10.1364/OME.7.000133es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/MINECO//FIS2014-56100-C2-1-P-
dc.relation.projectIDinfo:eu-repo/grantAgreement/MINECO//FIS2015-66570-P-
Aparece en las colecciones:INV - GHPO - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailOMEX_v7_n1_pp_133-147_2017.pdfArtículo3,86 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.