Reliability in perimetric multichannel contrast sensitivity measurements

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/46347
Información del item - Informació de l'item - Item information
Título: Reliability in perimetric multichannel contrast sensitivity measurements
Autor/es: Fez Saiz, Dolores de | Capilla Perea, Pascual | Camps, Vicente J. | Luque Cobija, María José | Moncho Gascón, Vicenta
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Multichannel perimetry | Repeatability | Reproducibility | Agreement | Contrast sensitivity
Área/s de conocimiento: Óptica
Fecha de publicación: nov-2014
Editor: Wiley
Cita bibliográfica: Clinical and Experimental Optometry. 2014, 97(6): 555-564. doi:10.1111/cxo.12193
Resumen: Background: In this study, the reliability of perimetric contrast sensitivity measurements favouring the achromatic, the red-green and the blue-yellow post-receptorial mechanisms was analysed. Methods: A new technique, multichannel ATD perimetry, provides spatial and temporal stimuli favouring the detection by an achromatic mechanism (A), from a magno or parvocellular origin or by a red-green (RG) chromatic mechanism, with a parvocellular origin or a blue-yellow (BY) mechanism, with a koniocellular origin. The repeatability and reproducibility of contrast sensitivity measurements with these stimuli were studied in a group of 40 healthy subjects. The analysis was carried out on 21 testing points within a 60° by 40° fovea-centred region of the visual field. Results: The within-observer repeatability for the four mechanisms studied is either good or excellent when the intra-class correlation coefficient (ICC) can be calculated. For the remaining points, the Friedman's test finds that the measurements are repeatable. The between-observer reproducibility was either excellent or good in cases where the ICC was applied and according to the Friedman's test all results were reproducible. Conclusions: The results obtained showed good repeatability and reproducibility with A, RG and BY stimuli, although with BY stimuli repeatability is slightly worse. Future studies on the diagnostic validity of this device are based on the fact that changes of sensitivity can be compared by means of a visual single task, contrast sensitivity measurement and using a common metric.
Patrocinador/es: The ATD multichannel perimeter was built thanks to the support of the Spanish Ministerio de Ciencia y Tecnología Grants DPI2000-0116-P4-02 and PTR 1995-0909-OP, in collaboration with INDUSTRIAS DE OPTICA SA (San Cugat del Vallés, Spain).
URI: http://hdl.handle.net/10045/46347
ISSN: 0816-4622 (Print) | 1444-0938 (Online)
DOI: 10.1111/cxo.12193
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2014 The Authors. Clinical and Experimental Optometry © 2014 Optometrists Association Australia
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1111/cxo.12193
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2014_de-Fez_etal_CEO_final.pdfVersión final (acceso restringido)351,77 kBAdobe PDFAbrir    Solicitar una copia
Thumbnail2014_de-Fez_etal_CEO_rev.pdfPreprint (acceso abierto)1,18 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.