Dispersive liquid–liquid microextraction combined with laser-induced breakdown spectrometry and inductively coupled plasma optical emission spectrometry to elemental analysis

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/46267
Información del item - Informació de l'item - Item information
Título: Dispersive liquid–liquid microextraction combined with laser-induced breakdown spectrometry and inductively coupled plasma optical emission spectrometry to elemental analysis
Autor/es: Gaubeur, Ivanise | Aguirre Pastor, Miguel Ángel | Kovachev, Nikolay | Hidalgo, Montserrat | Canals, Antonio
Grupo/s de investigación o GITE: Espectroscopía Atómica-Masas y Química Analítica en Condiciones Extremas
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología | Universidad de Alicante. Instituto Universitario de Materiales
Palabras clave: Laser-induced breakdown spectrometry | Inductively coupled plasma optical emission spectrometry | Dispersive liquid–liquid microextraction | Trace elemental analysis
Área/s de conocimiento: Química Analítica
Fecha de publicación: jul-2015
Editor: Elsevier
Cita bibliográfica: Microchemical Journal. 2015, 121: 219-226. doi:10.1016/j.microc.2015.03.007
Resumen: In this paper, two analytical methodologies based on the combination of dispersive liquid–liquid microextraction with inductively coupled plasma optical emission spectrometry and laser-induced breakdown spectrometry, respectively, were evaluated for simultaneous preconcentration and detection of Cd, Co, Ni, Pb and Zn. The microextraction procedure was based on the injection of appropriate quantities of 1-undecanol and methanol into the sample solution containing the complexes formed between metal ions and 1-(2-pyridylazo) 2-naphtol (PAN). The main experimental factors affecting the complexation and the extraction of metals (pH, PAN concentration, salt addition and extractant solvent and disperser solvent volume) were optimized using a multivariate analysis consisting of two steps: a Plackett-Burman design followed by a Circumscribed Central Composite Design (CCCD). Under optimum microextraction conditions, the analytical features of the proposed methodologies were assessed. Accuracy was evaluated by analyzing two certified reference materials, yielding results in agreement with the certified values. Both methodologies were applied to the analysis of a number of beverage samples.
Patrocinador/es: National Council for Scientific and Technological Development (Brazil) (CNPq – Science without Borders project no. 245782/2012-5). São Paulo Foundation Research (FAPESP project no. 2011/19730-3). This research has been supported by Government of Spain (CTQ2011-23968) and Regional Government of Valencia (Spain) (ACOMP/2013/072).
URI: http://hdl.handle.net/10045/46267
ISSN: 0026-265X (Print) | 1095-9149 (Online)
DOI: 10.1016/j.microc.2015.03.007
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2015 Elsevier B.V.
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1016/j.microc.2015.03.007
Aparece en las colecciones:INV - SP-BG - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2015_Gaubeur_etal_Microchemical-Journal_final.pdfVersión final (acceso restringido)444,07 kBAdobe PDFAbrir    Solicitar una copia
Thumbnail2015_Gaubeur_etal_Microchemical-Journal_accepted.pdfAccepted Manuscript (acceso abierto)459,9 kBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.