The posterior chamber phakic refractive lens (PRL): a review
Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/10045/39231
Título: | The posterior chamber phakic refractive lens (PRL): a review |
---|---|
Autor/es: | Pérez Cambrodí, Rafael J. | Piñero, David P. | Ferrer Blasco, Teresa | Cerviño, Alejandro | Brautaset, Rune |
Grupo/s de investigación o GITE: | Grupo de Óptica y Percepción Visual (GOPV) |
Centro, Departamento o Servicio: | Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía |
Palabras clave: | Posterior chamber phakic intraocular lens | Phakic refractive lens (PRL) | Refractive surgery | Review | Optical quality | Visual performance |
Área/s de conocimiento: | Óptica |
Fecha de publicación: | 2013 |
Editor: | Macmillan Publishers |
Cita bibliográfica: | Eye. 2013, 27: 14-21. doi:10.1038/eye.2012.235 |
Resumen: | Implantation of phakic intraocular lenses (pIOLs) is a reversible refractive procedure, preserving the patient’s accommodative function with minimal induction of higher order aberrations compared with corneal photoablative procedures. Despite this, as an intraocular procedure, it has potential risks such as cataracts, chronic uveitis, pupil ovalization, corneal endothelial cell loss, pigmentary dispersion syndrome, pupillary block glaucoma, astigmatism, or endophthalmitis. Currently, only two models of posterior chamber pIOLs are commercially available, the implantable collammer lens (STAAR Surgical Co.) and the phakic refractive lens (PRL; Zeiss Meditec). The number of published reports on the latter is very low, and some concerns still remain about its long-term safety. The present article reviews the published literature on the outcomes after PRL implantation in order to provide a general overview and evaluate its real potential as a surgical refractive option. |
URI: | http://hdl.handle.net/10045/39231 |
ISSN: | 0950-222X (Print) | 1476-5454 (Online) |
DOI: | 10.1038/eye.2012.235 |
Idioma: | eng |
Tipo: | info:eu-repo/semantics/article |
Derechos: | © 2013 Macmillan Publishers Limited All rights reserved |
Revisión científica: | si |
Versión del editor: | http://dx.doi.org/10.1038/eye.2012.235 |
Aparece en las colecciones: | INV - GOPV - Artículos de Revistas |
Archivos en este ítem:
Archivo | Descripción | Tamaño | Formato | |
---|---|---|---|---|
2013_Perez-Cambrodi_etal_Eye_final.pdf | Versión final (acceso restringido) | 338,03 kB | Adobe PDF | Abrir Solicitar una copia |
Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.