Exploring the electrochemical performance of graphitic paste electrodes: graphene vs. graphite

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/38724
Registro completo de metadatos
Registro completo de metadatos
Campo DCValorIdioma
dc.contributorElectroquímica Aplicada y Electrocatálisises
dc.contributor.authorFigueiredo-Filho, Luiz C.S.-
dc.contributor.authorBrownson, Dale A.C.-
dc.contributor.authorGomez-Mingot, Maria-
dc.contributor.authorIniesta, Jesus-
dc.contributor.authorFatibello-Filho, Orlando-
dc.contributor.authorBanks, Craig E.-
dc.contributor.otherUniversidad de Alicante. Departamento de Química Físicaes
dc.contributor.otherUniversidad de Alicante. Instituto Universitario de Electroquímicaes
dc.date.accessioned2014-07-07T08:37:24Z-
dc.date.available2014-07-07T08:37:24Z-
dc.date.issued2013-09-06-
dc.identifier.citationAnalyst. 2013,138: 6354-6364. doi:10.1039/C3AN00950Ees
dc.identifier.issn0003-2654 (Print)-
dc.identifier.issn1364-5528 (Online)-
dc.identifier.urihttp://hdl.handle.net/10045/38724-
dc.description.abstractWe report the fabrication, characterisation (SEM, TEM, XPS and Raman spectroscopy) and electrochemical implementation of a graphene paste electrode. The paste electrodes utilised are constructed by simply mixing graphene with mineral oil (which acts as a binder) prior to loading the resultant paste into a piston-driven polymeric-tubing electrode-shell, where this electrode configuration allows for rapid renewal of the electrode surface. The fabricated paste electrode is electrochemically characterised using both inner-sphere and outer-sphere redox probes, namely potassium ferrocyanide(II), hexaammine-ruthenium(III) chloride and hexachloroiridate(III), in addition to the biologically relevant and electroactive analytes, L-ascorbic acid (AA) and uric acid (UA). Comparisons are made with a graphite paste alternative and the benefits of graphene implementation as a paste electrode within electrochemistry are explored, as well as the characterisation of their electroanalytical performances. We reveal no observable differences in the electrochemical performance and thus suggest that there are no advantages of using graphene over graphite in the fabrication of paste electrodes. Such work is highly important and informative for those working in the field of electroanalysis where electrochemistry can provide portable, rapid, reliable and accurate sensing protocols (bringing the laboratory into the field), with particular relevance to those searching for new electrode materials.es
dc.languageenges
dc.publisherRoyal Society of Chemistryes
dc.rights© Royal Society of Chemistry 2013es
dc.subjectGraphenees
dc.subjectGraphitees
dc.subjectPaste electrodeses
dc.subjectElectrochemicales
dc.subject.otherQuímica Físicaes
dc.titleExploring the electrochemical performance of graphitic paste electrodes: graphene vs. graphitees
dc.typeinfo:eu-repo/semantics/articlees
dc.peerreviewedsies
dc.identifier.doi10.1039/C3AN00950E-
dc.relation.publisherversionhttp://dx.doi.org/10.1039/C3AN00950Ees
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses
Aparece en las colecciones:INV - LEQA - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2013_Figueiredo_etal_Analyst_final.pdfVersión final (acceso restringido)617,28 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.