Determination of metallic nanoparticles in air filters by means single particle inductively coupled plasma mass spectrometry

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/126153
Información del item - Informació de l'item - Item information
Título: Determination of metallic nanoparticles in air filters by means single particle inductively coupled plasma mass spectrometry
Autor/es: Torregrosa Carretero, Daniel | Grindlay, Guillermo | Guardia, Miguel de la | Gras, Luis | Mora, Juan
Grupo/s de investigación o GITE: Espectrometría Atómica Analítica (GEAA)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología
Palabras clave: Metallic nanoparticles | Air quality monitoring | Filters | Single particle | Inductively coupled plasma mass spectrometry
Fecha de publicación: 11-ago-2022
Editor: Elsevier
Cita bibliográfica: Talanta. 2023, 252: 123818. https://doi.org/10.1016/j.talanta.2022.123818
Resumen: Single particle inductively coupled plasma mass spectrometry (spICP-MS) has been explored for the determination of metallic nanoparticles (NPs) in air. Different extraction strategies (i.e., direct immersion, hard cap espresso, ultrasound-assisted and microwave-assisted extraction) and extracting solvents (i.e., citric acid, trisodium citrate, potassium nitrate, sodium nitrate, thiourea, disodium pyrophosphate and ammonium hydroxide) were investigated for platinum and gold NPs recovery from glass and microquartz fiber filters with a nominal size cut-off of 300 nm. Results show that metallic NPs are preserved and quantitatively extracted from the filter in 4 min inside an 800 W microwave oven by using 40 mL of a 2.0% w w−1 NH4OH solution. For the remaining extraction procedures, either incomplete recoveries or NPs degradation occur. As regards the influence of filter material, microquartz fiber affords better NPs capturing performance than glass fiber ones, enabling the quantification of NPs with diameters above 28 nm. This methodology has been successfully applied to determine PtNPs in filters from environmental monitoring stations and to gain insight into NPs transport through ICP-MS sample introduction system. Care should be taken during spICP-MS calibration since biased results might be obtained due to differences on NPs transport efficiency between standards and samples.
Patrocinador/es: The authors would like to thank the Generalitat Valenciana (PROMETEO/2021/055) and the Vice-Presidency for Research and Knowledge Transfer of the University of Alicante for the financial support of this work (Projects GRE12-19 and VIGROB-050). D. Torregrosa thanks the Spanish Ministerio de Ciencia, Innovación y Universidades for the fellowship FPU17/02853.
URI: http://hdl.handle.net/10045/126153
ISSN: 0039-9140 (Print) | 1873-3573 (Online)
DOI: 10.1016/j.talanta.2022.123818
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2022 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Revisión científica: si
Versión del editor: https://doi.org/10.1016/j.talanta.2022.123818
Aparece en las colecciones:INV - GEAA - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailTorregrosa_etal_2022_Talanta.pdf1,61 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.