Muscle Activation in Middle-Distance Athletes with Compression Stockings

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/103534
Información del item - Informació de l'item - Item information
Título: Muscle Activation in Middle-Distance Athletes with Compression Stockings
Autor/es: Moreno Pérez, Diego | Marín, Pedro J. | López-Samanes, Álvaro | Cejuela, Roberto | Esteve-Lanao, Jonathan
Grupo/s de investigación o GITE: Research in Physical Education, Fitness and Performance (RIPEFAP)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Didáctica General y Didácticas Específicas
Palabras clave: Surface electromyography | Compression garment | Gradual-elastic compression stockings | Muscular fatigue | Endurance athletes
Área/s de conocimiento: Educación Física y Deportiva
Fecha de publicación: 26-feb-2020
Editor: MDPI
Cita bibliográfica: Moreno-Pérez D, Marín PJ, López-Samanes Á, Cejuela-Anta R, Esteve-Lanao J. Muscle Activation in Middle-Distance Athletes with Compression Stockings. Sensors. 2020; 20(5):1268. doi:10.3390/s20051268
Resumen: The aim of this study was to evaluate changes in electromyographic activity with the use of gradual compression stockings (GCSs) on middle-distance endurance athletes’ performance, based on surface electromyography measurement techniques. Sixteen well-trained athletes were recruited (mean ± SD: age 33.4 ± 6.3 years, VO2max 63.7 ± 6.3 mL·kg−1·min−1, maximal aerobic speed 19.7 ± 1.5 km·h). The athletes were divided into two groups and were assigned in a randomized order to their respective groups according to their experience with the use of GCSs. Initially, a maximum oxygen consumption (VO2max) test was performed to standardize the athletes’ running speeds for subsequent tests. Afterward, electromyographic activity, metabolic, and performance variables for each group were measured with surface electromyography. In addition, blood lactate concentration was measured, both with and without GCSs, during 10 min at 3% above VT2 (second ventilatory threshold), all of which were performed on the track. Next, surface electromyography activity was measured during a 1 km run at maximum speed. No significant changes were found in electromyography activity, metabolic and performance variables with GCSs use (p > 0.164) in any of the variables measured. Overall, there were no performance benefits when using compression garments against a control condition.
URI: http://hdl.handle.net/10045/103534
ISSN: 1424-8220
DOI: 10.3390/s20051268
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Revisión científica: si
Versión del editor: https://doi.org/10.3390/s20051268
Aparece en las colecciones:INV - SCAPE - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2020_Moreno-Perez_etal_Sensors.pdf254,54 kBAdobe PDFAbrir Vista previa


Este ítem está licenciado bajo Licencia Creative Commons Creative Commons