Inter-rater reliability of trained and untrained raters for measuring jump height with the MyJump app

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/77068
Información del item - Informació de l'item - Item information
Title: Inter-rater reliability of trained and untrained raters for measuring jump height with the MyJump app
Authors: Pueo, Basilio | Jimenez-Olmedo, Jose Manuel | Penichet-Tomás, Alfonso | Bernal-Soriano, Mari Carmen
Research Group/s: Research in Physical Education, Fitness and Performance (RIPEFAP)
Center, Department or Service: Universidad de Alicante. Departamento de Didáctica General y Didácticas Específicas
Keywords: Instrumentation | Agreement | Consistency | Smartphone | Measure | Observation
Knowledge Area: Educación Física y Deportiva
Issue Date: 30-Jun-2018
Publisher: University of Piteşti, Romania
Citation: Journal of Physical Education and Sport (JPES). 2018, 18(2), Art 121: 821-824. doi:10.7752/jpes.2018.02121
Abstract: Smartphone apps have been very popular among researchers, coaches and clinicians. The aim of this study was to analyze the inter-rater reliability of trained and untrained raters of the iOs app MyJump. Eighteen participants completed eight counter-movement jumps (CMJ) each (n=144) which were recorded using the app. In order to examine inter-rater reliability derived from raters’ experience, independent assessments were obtained by an untrained rater and two trained raters of the same recordings. Results showed very high agreement between trained raters (ICC=0.982, α=0.991) and between trained and untrained raters (ICC=0.984, α=0.992). Bland-Altman plots depicted negligible bias between both types of raters. Finally, very good internal consistency was found, regardless of experience (α from 0.995 to 0.997 and CV from 1.1 to 1.4%). This study have shown no significant difference in performance of trained and untrained raters of MyJump, and therefore no special training must be observed for an accurate use of the app.
URI: http://hdl.handle.net/10045/77068
ISSN: 2247-8051 (Print) | 2247-806X (Online)
DOI: 10.7752/jpes.2018.02121
Language: eng
Type: info:eu-repo/semantics/article
Rights: This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0
Peer Review: si
Publisher version: https://doi.org/10.7752/jpes.2018.02121
Appears in Collections:INV - SCAPE - Artículos de Revistas