Evaluation of calcium-, carbon- and sulfur-based non-spectral interferences in high-power MIP-OES: comparison with ICP-OES

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/95593
Información del item - Informació de l'item - Item information
Título: Evaluation of calcium-, carbon- and sulfur-based non-spectral interferences in high-power MIP-OES: comparison with ICP-OES
Autor/es: Serrano, Raquel | Grindlay, Guillermo | Gras, Luis | Mora, Juan
Grupo/s de investigación o GITE: Espectrometría Atómica Analítica (GEAA)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología
Palabras clave: Calcium | Carbon | Sulfur | Non-spectral interferences | MIP-OES | ICP-OES
Área/s de conocimiento: Química Analítica
Fecha de publicación: 24-may-2019
Editor: Royal Society of Chemistry
Cita bibliográfica: Journal of Analytical Atomic Spectrometry. 2019, 34: 1611-1617. doi:10.1039/C9JA00148D
Resumen: Fundamental studies about non-spectral interferences in high-power microwave induced plasma optical emission spectrometry (MIP-OES) are very limited so far. The goal of this work is to investigate non-spectral interferences originating from calcium (0.5% w w−1 calcium nitrate), carbon (5.0% w w−1 glycerol) and sulfur (5.0% w w−1 sulfuric acid) matrices in commercial high-power MIP-OES based on a Hammer cavity. To this end, the influence of the nebulizer gas flow rate on the signal of several atomic and ionic lines of a total of 10 elements (As, Co, Cu, Mg, Mn, Mo, Sc, Se, Sr and Zn) has been studied for each matrix. Compared to the 1.0% w w−1 nitric acid reference solution, the emission signal for atomic lines with Esum values lower than 3.26 eV was enhanced in the presence of calcium but it was suppressed for the remaining atomic and ionic lines tested. Calcium matrix effects originate from changes in both plasma excitation conditions and ion–atom equilibrium. With regard to the 5.0% w w−1 glycerol and 5.0% w w−1 sulfuric acid solutions, no signal changes were noticed for the 1.0% w w−1 nitric acid solution since no significant differences were observed either in the aerosol size and transport or in the plasma excitation conditions. A comparison of matrix effects in MIP-OES with those obtained in inductively coupled plasma optical emission spectrometry (ICP-OES) under similar experimental conditions reveals that the former source is more sensitive to the presence of the calcium matrix. In contrast, MIP-OES is a more robust technique for elemental analysis when operating with 5.0% w w−1 glycerol and 5.0% w w−1 sulfuric acid solutions. In fact, matrix-based signal enhancements observed in ICP-OES for As and Se are eliminated when operating in MIP-OES.
Patrocinador/es: The authors would like to thank Agilent–Spain and ISI Science (Oviedo, Spain) for access to the 4200 MP-OES as well as the Vice-Presidency for Research and Knowledge Transfer of the University of Alicante – Spain for the financial support of this work.
URI: http://hdl.handle.net/10045/95593
ISSN: 0267-9477 (Print) | 1364-5544 (Online)
DOI: 10.1039/C9JA00148D
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © The Royal Society of Chemistry 2019
Revisión científica: si
Versión del editor: https://doi.org/10.1039/C9JA00148D
Aparece en las colecciones:INV - GEAA - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2019_Serrano_etal_JAnalAtSpectrom_final.pdfVersión final (acceso restringido)807,16 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.