Interchangeability of corneal curvature and asphericity measurements provided by three different devices

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/89477
Información del item - Informació de l'item - Item information
Title: Interchangeability of corneal curvature and asphericity measurements provided by three different devices
Authors: Piñero, David P. | Soto-Negro, Roberto | Ruiz Fortes, Pedro | Pérez Cambrodí, Rafael J. | Fukumitsu, Hideki
Research Group/s: Grupo de Óptica y Percepción Visual (GOPV)
Center, Department or Service: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Keywords: Astigmatism | Corneal topography | Keratometry | Corneal asphericity
Knowledge Area: Óptica
Issue Date: 18-Mar-2019
Publisher: IJO Press
Citation: International Journal of Ophthalmology. 2019, 12(3): 412-416. doi:10.18240/ijo.2019.03.10
Abstract: AIM: To evaluate the interchangeability of keratometric and asphericity measurements provided by three measurement systems based on different optical principles. METHODS: A total of 40 eyes of 40 patients with a mean age of 34.1y were included. In all cases, a corneal curvature analysis was performed with IOL-Master (IOLM), iDesign 2 (ID2), and Sirius systems (SIR). Differences between instruments for flattest (K1) and steepest (K2) keratometric readings, as well as for magnitude and axis of corneal astigmatism were analyzed. Likewise, differences in asphericity (Q) between SIR and ID2 were also evaluated. RESULTS: Mean differences between devices for K1 were 0.20±0.21 (P<0.001), -0.12±0.36 (P=0.046) and -0.32±0.36 D (P<0.001) for the comparisons IOLM-SIR, IOLM-ID2 and SIR-ID2, respectively. The ranges of agreement for these comparisons between instruments were 0.41, 0.70, and 0.70 D. For K2, mean differences were 0.31±0.33 (P<0.001), -0.08±0.43 (P=0.265) and -0.39±0.38 D (P<0.001), with ranges of agreement of 0.65, 0.84, and 0.74 D. Concerning magnitude of astigmatism, ranges of agreement were in the limit of clinical relevance (0.49 D, P=0.011; 0.55 D, P=0.386; 0.43 D, P=0.05). In contrast, ranges of agreement were clinically relevant for astigmatic axis (26.68o, 33.83o and 18.37o, P≥0.121) and for Q between SIR and ID2 (0.16, P<0.001). CONCLUSION: The keratometric corneal power, astigmatic axis and asphericity measurements provide by the three systems evaluated cannot be considered as interchangeable, whereas measurements of corneal astigmatism obtained with SIR and ID2 can be considered as interchangeable for clinical purposes.
Sponsor: The author David P. Piñero has been supported by the Ministry of Economy, Industry and Competitiveness of Spain within the program Ramón y Cajal, RYC-2016-20471. Additionally he received an unrestricted grant from Johnson and Johnson Vision for the performance of this research.
URI: http://hdl.handle.net/10045/89477
ISSN: 2222-3959 (Print) | 2227-4898 (Online)
DOI: 10.18240/ijo.2019.03.10
Language: eng
Type: info:eu-repo/semantics/article
Rights: © IJO Press Co., Limited
Peer Review: si
Publisher version: https://doi.org/10.18240/ijo.2019.03.10
Appears in Collections:INV - GOPV - Artículos de Revistas
INV - GIOptom - Artículos de Revistas

Files in This Item:
Files in This Item:
File Description SizeFormat 
Thumbnail2019_Pinero_etal_IntJOphthalmol.pdf396,67 kBAdobe PDFOpen Preview


Items in RUA are protected by copyright, with all rights reserved, unless otherwise indicated.