Validation of keratometric measurements obtained with an intraoperative image-guided system: intra-session repeatability and interchangeability with an optical biometer

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/73953
Información del item - Informació de l'item - Item information
Título: Validation of keratometric measurements obtained with an intraoperative image-guided system: intra-session repeatability and interchangeability with an optical biometer
Autor/es: Ruiz-Belda, Clara | Rodrigo-Auría, Fermín | Piñero, David P.
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Astigmatism | Corneal curvature | Keratometry | Optical biometry | Verion system
Área/s de conocimiento: Óptica
Fecha de publicación: mar-2018
Editor: Wiley
Cita bibliográfica: Clinical and Experimental Optometry. 2018, 101(2): 200-205. doi:10.1111/cxo.12623
Resumen: Purpose: To evaluate the intra-session repeatability of keratometric measurements obtained in healthy eyes with the Verion image-guided system (Alcon Laboratories Inc, Fort Worth, Texas, USA) as well as the interchangeability of such measurements with those obtained with an optical biometer (Aladdin, Topcon, Tokyo, Japan). Methods: A total of 53 eyes of 53 patients (age 31–67 years) were enrolled in the study. All eyes received a comprehensive ophthalmologic examination including an analysis with the Verion image-guided and Aladdin systems. Three consecutive measurements of keratometry were obtained with the Verion system to assess the intra-session repeatability. Within-subject standard deviation (Sw) and intraobserver precision (± 1.96 × Sw) were calculated. Bland–Altman analysis was used for the interchangeability analysis. Results: Mean Sw was 0.26, 0.24 and 0.10 D for the keratometric power in the flattest meridian (K1), keratometric power in the steepest meridian (K2) and astigmatism, respectively. Mean Sw was 4.29° for the axis of the flattest corneal meridian (AX1). Statistically significant but clinically acceptable differences were found in K1, K2 and keratometric astigmatism among systems (p < 0.01). In contrast, differences among systems in AX1 were not statistically significant (p = 0.385) but clinically relevant (mean difference: 15.74°; limits of agreement: −30.93 to 62.41°). Conclusions: The Verion system provides consistent measurements of keratometric parameters, with measurements of AX1 that are not interchangeable with that provided by the optical biometer Aladdin, especially in cases of low and oblique astigmatism.
URI: http://hdl.handle.net/10045/73953
ISSN: 0816-4622 (Print) | 1444-0938 (Online)
DOI: 10.1111/cxo.12623
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2017 Optometry Australia
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1111/cxo.12623
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2018_Ruiz-Belda_etal_ClinExpOptom_final.pdfVersión final (acceso restringido)431,71 kBAdobe PDFAbrir    Solicitar una copia
Thumbnail2018_Ruiz-Belda_etal_ClinExpOptom_preprint.pdfPreprint (acceso abierto)1,79 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.