Magnetic headspace adsorptive extraction of chlorobenzenes prior to thermal desorption gas chromatography-mass spectrometry

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/66395
Información del item - Informació de l'item - Item information
Título: Magnetic headspace adsorptive extraction of chlorobenzenes prior to thermal desorption gas chromatography-mass spectrometry
Autor/es: Vidal, Lorena | Ahmadi, Mazaher | Fernández Martínez, Elena | Madrakian, Tayyebeh | Canals, Antonio
Grupo/s de investigación o GITE: Espectroscopía Atómica-Masas y Química Analítica en Condiciones Extremas
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología | Universidad de Alicante. Instituto Universitario de Materiales
Palabras clave: Solid-phase microextraction | Chlorobenzenes | Magnetic graphene oxide | Magnetic headspace adsorptive extraction | Gas chromatography-mass spectrometry | Water samples
Área/s de conocimiento: Nutrición y Bromatología | Química Analítica
Fecha de publicación: 8-jun-2017
Editor: Elsevier
Cita bibliográfica: Analytica Chimica Acta. 2017, 971: 40-47. doi:10.1016/j.aca.2017.04.002
Resumen: This study presents a new, user-friendly, cost-effective and portable headspace solid-phase extraction technique based on graphene oxide decorated with iron oxide magnetic nanoparticles as sorbent, located on one end of a small neodymium magnet. Hence, the new headspace solid-phase extraction technique has been called Magnetic Headspace Adsorptive Extraction (Mag-HSAE). In order to assess Mag-HSAE technique applicability to model analytes, some chlorobenzenes were extracted from water samples prior to gas chromatography-mass spectrometry determination. A multivariate approach was employed to optimize the experimental parameters affecting Mag-HSAE. The method was evaluated under optimized extraction conditions (i.e., sample volume, 20 mL; extraction time, 30 min; sorbent amount, 10 mg; stirring speed, 1500 rpm, and ionic strength, non-significant), obtaining a linear response from 0.5 to 100 ng L−1 for 1,3-DCB, 1,4-DCB, 1,2-DCB, 1,3,5-TCB, 1,2,4-TCB and 1,2,3-TCB; from 0.5 to 75 ng L−1 for 1,2,4,5-TeCB, and PeCB; and from 1 to 75 ng L−1 for 1,2,3,4-TeCB. The repeatability of the proposed method was evaluated at 10 ng L−1 and 50 ng L−1 spiking levels, and coefficients of variation ranged between 1.5 and 9.5% (n = 5). Limits of detection values were found between 93 and 301 pg L−1. Finally, tap, mineral and effluent water were selected as real water samples to assess method applicability. Relative recoveries varied between 86 and 110% showing negligible matrix effects.
Patrocinador/es: The authors would like to thank the Spanish Ministry of Science and Innovation (project n. CTQ2011-23968), Generalitat Valenciana (project n. PROMETEO/2013/038) for the financial support. M. Ahmadi would like to thank Iranian Ministry of Science, Research, and Technology for the travel grant. E. Fernández thanks Spanish Ministry of Education for her FPU grant (FPU13/03125).
URI: http://hdl.handle.net/10045/66395
ISSN: 0003-2670 (Print) | 1873-4324 (Online)
DOI: 10.1016/j.aca.2017.04.002
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2017 Elsevier B.V.
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1016/j.aca.2017.04.002
Aparece en las colecciones:INV - SP-BG - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2017_Vidal_etal_AnalytChimActa_final.pdfVersión final (acceso restringido)1,09 MBAdobe PDFAbrir    Solicitar una copia
Thumbnail2017_Vidal_etal_AnalytChimActa_revised.pdfVersión revisada (acceso abierto)1,29 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.