Corneal Topographic and Aberrometric Measurements Obtained with a Multidiagnostic Device in Healthy Eyes: Intrasession Repeatability

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/61588
Registre complet
Registre complet
Camp Dublin Core Valor Idioma
dc.contributorGrupo de Óptica y Percepción Visual (GOPV)es_ES
dc.contributor.authorPiñero, David P.-
dc.contributor.authorLópez Navarro, Alberto-
dc.contributor.authorCabezos, Inmaculada-
dc.contributor.authorFez Saiz, Dolores de-
dc.contributor.authorCaballero, María T.-
dc.contributor.authorCamps, Vicente J.-
dc.contributor.otherUniversidad de Alicante. Departamento de Óptica, Farmacología y Anatomíaes_ES
dc.date.accessioned2017-01-11T07:32:25Z-
dc.date.available2017-01-11T07:32:25Z-
dc.date.issued2017-
dc.identifier.citationJournal of Ophthalmology. Volume 2017 (2017), Article ID 2149145, 9 pages. doi:10.1155/2017/2149145es_ES
dc.identifier.issn2090-004X (Print)-
dc.identifier.issn2090-0058 (Online)-
dc.identifier.urihttp://hdl.handle.net/10045/61588-
dc.description.abstractPurpose. To evaluate the intrasession repeatability of corneal curvature, eccentricity, and aberrometric measurements obtained with a multidiagnostic device in healthy eyes. Methods. This study enrolled 107 eyes of 107 patients ranging in age from 23 to 65 years. All of them underwent a complete anterior segment examination with the VX120 system (Visionix-Luneau Technologies, Chartres, France). Three consecutive measurements were obtained. The within-subject standard deviation (Sw), intrasubject precision (1.96xSw), and intraclass correlation coefficient (ICC) were calculated. Results. All Sw for corneal power measurements were below 0.26 D, with ICC above 0.982. The Sw for corneal astigmatism at different areas (3, 5, and 7 mm) was below 0.21 D, with ICC above 0.913. Concerning the axis of astigmatism, its Sw was below 11.27°, with ICC above 0.975. The Sw and ICC for corneal eccentricity were 0.067 and 0.957, respectively. The Sw and ICC for high-order aberration root mean square (RMS) were 0.048 µm and 0.901, respectively. For 3rd- and 4th-order aberrometric parameters, all Sw were below 0.037 µm and all ICC were higher than 0.84, except for quadrafoil RMS (ICC: 0.689). Conclusions. The multidiagnostic device evaluated is able to provide consistent measurements of corneal power, eccentricity, and third- and fourth-order aberrations in healthy eyes.es_ES
dc.languageenges_ES
dc.publisherHindawi Publishing Corporationes_ES
dc.rights© 2017 David P. Piñero et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.es_ES
dc.subjectCorneales_ES
dc.subjectTopographices_ES
dc.subjectAberrometrices_ES
dc.subjectMultidiagnostic devicees_ES
dc.subjectHealthy eyeses_ES
dc.subject.otherÓpticaes_ES
dc.titleCorneal Topographic and Aberrometric Measurements Obtained with a Multidiagnostic Device in Healthy Eyes: Intrasession Repeatabilityes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.peerreviewedsies_ES
dc.identifier.doi10.1155/2017/2149145-
dc.relation.publisherversionhttp://dx.doi.org/10.1155/2017/2149145es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
Apareix a la col·lecció: INV - GOPV - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
Thumbnail2017_Pinero_etal_JOphtalm.pdf1,98 MBAdobe PDFObrir Vista prèvia


Aquest ítem està subjecte a una llicència de Creative Commons Llicència Creative Commons Creative Commons