Minimizing the IOL Power Error Induced by Keratometric Power

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/39224
Información del item - Informació de l'item - Item information
Título: Minimizing the IOL Power Error Induced by Keratometric Power
Autor/es: Camps, Vicente J. | Piñero, David P. | Fez Saiz, Dolores de | Mateo Pérez, Verónica
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Intraocular lens | IOL power | IOL power calculation | HofferQ | Holladay | Haigis | SRK-T
Área/s de conocimiento: Óptica
Fecha de publicación: jul-2013
Editor: American Academy of Optometry | Lippincott Williams & Wilkins
Cita bibliográfica: Optometry & Vision Science. 2013, 90(7): 639-649. doi:10.1097/OPX.0b013e3182972f50
Resumen: Purpose. To evaluate theoretically in normal eyes the influence on IOL power (PIOL) calculation of the use of a keratometric index (nk) and to analyze and validate preliminarily the use of an adjusted keratometric index (nkadj) in the IOL power calculation (PIOLadj). Methods. A model of variable keratometric index (nkadj) for corneal power calculation (Pc) was used for IOL power calculation (named PIOLadj). Theoretical differences ($PIOL) between the new proposed formula (PIOLadj) and which is obtained through Gaussian optics (PIOL Gauss) were determined using Gullstrand and Le Grand eye models. The proposed new formula for IOL power calculation (PIOLadj) was prevalidated clinically in 81 eyes of 81 candidates for corneal refractive surgery and compared with Haigis, HofferQ, Holladay, and SRK/T formulas. Results. A theoretical PIOL underestimation greater than 0.5 diopters was present in most of the cases when nk = 1.3375 was used. If nkadj was used for Pc calculation, a maximal calculated error in $PIOL of T0.5 diopters at corneal vertex in most cases was observed independently from the eye model, r1c, and the desired postoperative refraction. The use of nkadj in IOL power calculation (PIOLadj) could be valid with effective lens position optimization nondependent of the corneal power. Conclusions. The use of a single value of nk for Pc calculation can lead to significant errors in PIOL calculation that may explain some IOL power overestimations with conventional formulas. These inaccuracies can be minimized by using the new PIOLadj based on the algorithm of nkadj.
URI: http://hdl.handle.net/10045/39224
ISSN: 1040-5488 (Print) | 1538-9235 (Online)
DOI: 10.1097/OPX.0b013e3182972f50
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2013 American Academy of Optometry
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1097/OPX.0b013e3182972f50
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2013_Camps_etal_OVS_final.pdfVersión final (acceso restringido)645,25 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.