Axial length association with corneoscleral sagittal height and scleral asymmetry

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/147591
Información del item - Informació de l'item - Item information
Título: Axial length association with corneoscleral sagittal height and scleral asymmetry
Autor/es: Martínez-Plaza, Elena | López-de la Rosa, Alberto | Molina-Martín, Ainhoa | Bataille, Laurent | Piñero, David P.
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Axial length | Cornea | Corneoscleral profile | Eye surface profiler | Sagittal height | Sclera
Fecha de publicación: 3-oct-2024
Editor: John Wiley & Sons
Cita bibliográfica: Ophthalmic and Physiological Optics. 2025, 45(1): 152-159. https://doi.org/10.1111/opo.13402
Resumen: Purpose: To determine how corneoscleral geometry changes with axial length and to assess the usefulness of including the sagittal configuration of the anterior segment when predicting the axial length. Methods: An observational study was performed including 96 healthy subjects (96 eyes). Axial length was calculated from optical biometry (IOL Master 500). Corneal curvature and scleral sagittal height parameters at 13, 14 and 15 mm were obtained automatically using corneoscleral topography (eye surface profiler; ESP). In addition, corneal and scleral sagittal heights at numerous locations (21 radii: 0–10 mm from the corneal apex at 12 angles: 0–330°) were calculated using the raw height data extracted from the ESP. The relationships between axial length and the study parameters were analysed using Pearson correlation analysis. The equations for the prediction of axial length were obtained by fitting multiple linear regression models. Results: The temporal-nasal scleral asymmetry at 13-, 14- and 15-mm chord lengths was significantly correlated with axial length (r2 ≤ 0.26; p < 0.001). Significant inverse correlations were found between the temporal scleral sagittal height and axial length (r2 ≤ 0.28; p ≤ 0.02). The nasal scleral sagittal height was not associated with axial length. Three significant multiple linear regression models were fitted based on spherical equivalent, corneal radius and scleral asymmetry at 13 (r2 = 0.79; p < 0.001), 14 (r2 = 0.80; p < 0.001) and 15 (r2 = 0.80; p < 0.001) mm chord lengths. Conclusions: Larger ocular globes show reduced temporal-nasal scleral asymmetry, mainly due to the lower sagittal height of the temporal sclera. Thus, the geometry of the temporal scleral may be a factor of interest during myopia progression.
Patrocinador/es: E.M.-P. has been supported by European Union-NextGenerationEU.
URI: http://hdl.handle.net/10045/147591
ISSN: 0275-5408 (Print) | 1475-1313 (Online)
DOI: 10.1111/opo.13402
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2024 The Author(s). Ophthalmic and Physiological Optics published by John Wiley & Sons Ltd on behalf of College of Optometrists. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Revisión científica: si
Versión del editor: https://doi.org/10.1111/opo.13402
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailMartinez‐Plaza_etal_2025_OphthalmicPhysiolOpt.pdf1,93 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.