Axial length association with corneoscleral sagittal height and scleral asymmetry

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/147591
Información del item - Informació de l'item - Item information
Title: Axial length association with corneoscleral sagittal height and scleral asymmetry
Authors: Martínez-Plaza, Elena | López-de la Rosa, Alberto | Molina-Martín, Ainhoa | Bataille, Laurent | Piñero, David P.
Research Group/s: Grupo de Óptica y Percepción Visual (GOPV)
Center, Department or Service: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Keywords: Axial length | Cornea | Corneoscleral profile | Eye surface profiler | Sagittal height | Sclera
Issue Date: 3-Oct-2024
Publisher: John Wiley & Sons
Citation: Ophthalmic and Physiological Optics. 2025, 45(1): 152-159. https://doi.org/10.1111/opo.13402
Abstract: Purpose: To determine how corneoscleral geometry changes with axial length and to assess the usefulness of including the sagittal configuration of the anterior segment when predicting the axial length. Methods: An observational study was performed including 96 healthy subjects (96 eyes). Axial length was calculated from optical biometry (IOL Master 500). Corneal curvature and scleral sagittal height parameters at 13, 14 and 15 mm were obtained automatically using corneoscleral topography (eye surface profiler; ESP). In addition, corneal and scleral sagittal heights at numerous locations (21 radii: 0–10 mm from the corneal apex at 12 angles: 0–330°) were calculated using the raw height data extracted from the ESP. The relationships between axial length and the study parameters were analysed using Pearson correlation analysis. The equations for the prediction of axial length were obtained by fitting multiple linear regression models. Results: The temporal-nasal scleral asymmetry at 13-, 14- and 15-mm chord lengths was significantly correlated with axial length (r2 ≤ 0.26; p < 0.001). Significant inverse correlations were found between the temporal scleral sagittal height and axial length (r2 ≤ 0.28; p ≤ 0.02). The nasal scleral sagittal height was not associated with axial length. Three significant multiple linear regression models were fitted based on spherical equivalent, corneal radius and scleral asymmetry at 13 (r2 = 0.79; p < 0.001), 14 (r2 = 0.80; p < 0.001) and 15 (r2 = 0.80; p < 0.001) mm chord lengths. Conclusions: Larger ocular globes show reduced temporal-nasal scleral asymmetry, mainly due to the lower sagittal height of the temporal sclera. Thus, the geometry of the temporal scleral may be a factor of interest during myopia progression.
Sponsor: E.M.-P. has been supported by European Union-NextGenerationEU.
URI: http://hdl.handle.net/10045/147591
ISSN: 0275-5408 (Print) | 1475-1313 (Online)
DOI: 10.1111/opo.13402
Language: eng
Type: info:eu-repo/semantics/article
Rights: © 2024 The Author(s). Ophthalmic and Physiological Optics published by John Wiley & Sons Ltd on behalf of College of Optometrists. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Peer Review: si
Publisher version: https://doi.org/10.1111/opo.13402
Appears in Collections:INV - GOPV - Artículos de Revistas

Files in This Item:
Files in This Item:
File Description SizeFormat 
ThumbnailMartinez‐Plaza_etal_2025_OphthalmicPhysiolOpt.pdf1,93 MBAdobe PDFOpen Preview


Items in RUA are protected by copyright, with all rights reserved, unless otherwise indicated.