Pilot Study Assessing the Safety and Acceptance of a Novel Virtual Reality System to Improve Visual Function
Empreu sempre aquest identificador per citar o enllaçar aquest ítem
http://hdl.handle.net/10045/141563
Títol: | Pilot Study Assessing the Safety and Acceptance of a Novel Virtual Reality System to Improve Visual Function |
---|---|
Autors: | Piñero, David P. | Leal-Vega, Luis | Molina-Martín, Ainhoa | Hernández Rodríguez, Carlos Javier | Cuadrado-Asensio, Rubén | Martín-Gutiérrez, Adrián | Arenillas, Juan F. | Coco-Martin, María Begoña |
Grups d'investigació o GITE: | Grupo de Óptica y Percepción Visual (GOPV) |
Centre, Departament o Servei: | Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía |
Paraules clau: | Accommodation | Convergence | Head mounted display | Phoria | Simulator sickness | Virtual reality |
Data de publicació: | 1-de març-2024 |
Editor: | Taylor & Francis |
Citació bibliogràfica: | Seminars in Ophthalmology. 2024, 39(5): 394-399. https://doi.org/10.1080/08820538.2024.2324074 |
Resum: | Purpose: To assess the feasibility of the clinical use of a novel Virtual Reality (VR) training software designed to be used for active vision therapy in amblyopic patients by determining its preliminary safety and acceptance on the visual function of healthy adults. Methods: Pilot study enrolling 10 individuals (3 men, 7 women, mean age: 31.8 ± 6.5 years) with a best corrected visual acuity (BCVA) of ≥ .90 (decimal) in both eyes were evaluated before and after 20 minutes of exposure to the NEIVATECH VR system using the HTC Vive Pro Eye head mounted display. Visual function assessment included near (40 cm) and distance (6 m) cover test (CT), stereopsis, binocular accommodative facility (BAF), near point of convergence (NPC), near point of accommodation (NPA), accommodative-convergence over accommodation (AC/A) ratio and positive and negative fusional vergences. Safety was assessed using the VR Sickness Questionnaire (VRSQ) and acceptance using the Technology Acceptance Model ;(TAM). Changes in all these variables after VR exposure were analyzed.Results: Short-term exposure to the NEIVATECH VR system only induced statistically significant changes in distance phoria (p = .016), but these changes were not clinically relevant. No significant changes were observed in VRSQ oculo-motricity and disorientation scores after exposure (p = .197 and .317, respectively). TAM scores showed a good acceptance of the system in terms of perceived enjoyment and perceived ease of use, although some concerns were raised in relation to the intention-to-use domain. Conclusion: Exposure to the NEIVATECH VR system does not seem to adversely affect the visual function in healthy adults and its safety and acceptance profile seems to be adequate for supporting its potential use in other populations, such as amblyopic patients. |
Patrocinadors: | This research was supported by the Centre for the Development of Industrial Technology (CDTI) of the Spanish Ministry of Science in the framework of the NEIVATECH project [Ref.: IDI-20181232] |
URI: | http://hdl.handle.net/10045/141563 |
ISSN: | 0882-0538 (Print) | 1744-5205 (Online) |
DOI: | 10.1080/08820538.2024.2324074 |
Idioma: | eng |
Tipus: | info:eu-repo/semantics/article |
Drets: | © 2024 Taylor & Francis |
Revisió científica: | si |
Versió de l'editor: | https://doi.org/10.1080/08820538.2024.2324074 |
Apareix a la col·lecció: | INV - GOPV - Artículos de Revistas |
Arxius per aquest ítem:
Arxiu | Descripció | Tamany | Format | |
---|---|---|---|---|
![]() | Versión final (acceso restringido) | 199,73 kB | Adobe PDF | Obrir Sol·licitar una còpia |
Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.