Minimum Clearance Distance in Fall Arrest Systems with Energy Absorber Lanyards

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/115327
Información del item - Informació de l'item - Item information
Título: Minimum Clearance Distance in Fall Arrest Systems with Energy Absorber Lanyards
Autor/es: Carrión Jackson, Elena | Ferrer, Belén | Monge, Juan F. | Saez, Pedro Ignacio | Pomares Torres, Juan Carlos | González Sánchez, Antonio
Grupo/s de investigación o GITE: Grupo de Ensayo, Simulación y Modelización de Estructuras (GRESMES) | Grupo de Análisis de Imagen, Sistemas Ópticos y Visión (IMAOS+V)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Ingeniería Civil
Palabras clave: Energy absorber lanyard | Fall arrest systems | Dynamic performance test | Clearance distance | Elastic and plastic deformation | High-speed camera
Área/s de conocimiento: Mecánica de Medios Continuos y Teoría de Estructuras
Fecha de publicación: 28-may-2021
Editor: MDPI
Cita bibliográfica: Carrión EÁ, Ferrer B, Monge JF, Saez PI, Pomares JC, González A. Minimum Clearance Distance in Fall Arrest Systems with Energy Absorber Lanyards. International Journal of Environmental Research and Public Health. 2021; 18(11):5823. https://doi.org/10.3390/ijerph18115823
Resumen: Accidents due to falls from height are one of the main causes of death in workplaces. Fall arrest systems (FAS) are designed to arrest the fall safely without injuring the accident victim. Their main mission is to restrain the body so as to prevent it from hitting the ground, generating forces and accelerations in the arrest process that are not harmful. A lack of empirical evidence and scant technical information provided by manufacturers regarding minimum clearance distance (MCD) below anchorage makes it necessary to study the safety distances required in the use of Energy Absorber Lanyards (EAL). This paper aims to determine the MCD below anchorage to arrest a fall using an EAL without hitting the ground. The real deformation of EAL when stopping a fall is studied. Ten EAL models distributed internationally by six manufacturers were chosen. Dynamic behavior tests were performed on the samples. Using image processing the total elongation of the equipment (elastic plus plastic) is obtained. The main conclusions are that maximum plastic elongation could be reduced by 29%. The method described in EN 355: 2002 underestimates elongation by up to 70% for some equipment 20% of EAL’s exceed the maximum arrest force (Fm) allowed in EN 355. The MCD data provided by manufacturers is not reliable. The data provided by manufacturers are incomplete. It is recommended that quality control for EAL’s be strengthened to ensure that products launched onto the market meet the requirement of EN355. The findings of this study recommended increasing MCD distance longer than that calculated according to EN355, at less than 1 m.
Patrocinador/es: This research was funded by UNIVERSITY OF ALICANTE and CENTRO DE INNOVACION VERTICAL S.A.C., grant number PC20-01A.
URI: http://hdl.handle.net/10045/115327
ISSN: 1660-4601
DOI: 10.3390/ijerph18115823
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Revisión científica: si
Versión del editor: https://doi.org/10.3390/ijerph18115823
Aparece en las colecciones:INV - GRESMES - Artículos de Revistas
INV - IMAOS+V - Artículos de Revistas
INV - BIMAEC - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailCarrion_etal_2021_IntJEnvironResPublicHealth.pdf1,25 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.