Ocular fixation and macular integrity by microperimetry in multiple sclerosis

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/111985
Full metadata record
Full metadata record
DC FieldValueLanguage
dc.contributorGrupo de Óptica y Percepción Visual (GOPV)es_ES
dc.contributor.authorGil-Casas, Amparo-
dc.contributor.authorPiñero, David P.-
dc.contributor.authorMolina-Martín, Ainhoa-
dc.contributor.otherUniversidad de Alicante. Departamento de Óptica, Farmacología y Anatomíaes_ES
dc.date.accessioned2021-01-15T11:36:31Z-
dc.date.available2021-01-15T11:36:31Z-
dc.date.issued2021-01-
dc.identifier.citationGraefe's Archive for Clinical and Experimental Ophthalmology. 2021, 259: 157-164. https://doi.org/10.1007/s00417-020-04948-6es_ES
dc.identifier.issn0721-832X (Print)-
dc.identifier.issn1435-702X (Online)-
dc.identifier.urihttp://hdl.handle.net/10045/111985-
dc.description.abstractPurpose To characterize the fixation and macular integrity of subjects with multiple sclerosis (MS) with and without previous optic neuritis (ON) using microperimetry (MP). Methods Fifty-five eyes of MS patients, subdivided into three groups (28 eyes without ON, 16 with previous ON, and 11 eyes with previous ON in the contralateral eye), and 43 healthy eyes were enrolled (January–November 2018). All cases were evaluated using the MAIA microperimeter (Centervue), analyzing the following parameters: average macular threshold (AT), fixation indexes (P1 and P2), bivariate contour ellipse area (BCEA) for 95% and 63% of points, and horizontal (H) and vertical (V) axes of the ellipse of fixation. Results All MS groups showed a significant reduced AT compared with the control group (p < 0.001). This reduction was more representative (p < 0.001) in eyes with previous ON. No statistically significant differences were found between MS patients with and without previous ON (p > 0.05). Mean AT was correlated with the examination time in all three groups (between ρ = − 0.798 p < 0.001 and ρ = − 0.49 p < 0.001). Significant differences in fixation parameters were only found between control and MS with ON groups (p < 0.02). The ratio of the disease showed a significant correlation with fixation parameters in MS groups (p < 0.02), but not with AT. Conclusions In MS patients, macular sensitivity is altered, especially in eyes with previous ON. Likewise, a fixational instability is present in MS patients with ON, with more increase of the V axis of the fixation area than of the H. The ratio of the disease also affects the patient fixation pattern.es_ES
dc.description.sponsorshipThe author David P Piñero has been supported by the Ministry of Economy, Industry and Competitiveness of Spain within the program Ramón y Cajal, RYC-2016-20471.es_ES
dc.languageenges_ES
dc.publisherSpringer Naturees_ES
dc.rights© Springer-Verlag GmbH Germany, part of Springer Nature 2020es_ES
dc.subjectMultiple sclerosises_ES
dc.subjectMicroperimetryes_ES
dc.subjectOcular fixationes_ES
dc.subjectMacular thresholdes_ES
dc.subjectPerimetryes_ES
dc.subject.otherÓpticaes_ES
dc.titleOcular fixation and macular integrity by microperimetry in multiple sclerosises_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.peerreviewedsies_ES
dc.identifier.doi10.1007/s00417-020-04948-6-
dc.relation.publisherversionhttps://doi.org/10.1007/s00417-020-04948-6es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/MINECO//RYC-2016-20471-
Appears in Collections:INV - GOPV - Artículos de Revistas

Files in This Item:
Files in This Item:
File Description SizeFormat 
ThumbnailGil-Casas_etal_2021_GraefesArchClinExpOphthalmol_final.pdfVersión final (acceso restringido)1,11 MBAdobe PDFOpen    Request a copy


Items in RUA are protected by copyright, with all rights reserved, unless otherwise indicated.