Repeatability of non-invasive break-up time measures with a new automated dry eye platform in healthy eyes

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/109771
Información del item - Informació de l'item - Item information
Title: Repeatability of non-invasive break-up time measures with a new automated dry eye platform in healthy eyes
Authors: Molina-Martín, Ainhoa | Fez Saiz, Dolores de | Piñero, David P.
Research Group/s: Grupo de Óptica y Percepción Visual (GOPV)
Center, Department or Service: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Keywords: Dry eye | VX120 | Non-invasive tear film break-up time | NIBUT | Tear meniscus height
Knowledge Area: Óptica
Issue Date: Nov-2020
Publisher: Springer Nature
Citation: International Ophthalmology. 2020, 40: 2855-2864. https://doi.org/10.1007/s10792-020-01470-w
Abstract: Purpose To evaluate the intrasession repeatability for non-invasive break-up time (NIBUT) and tear meniscus height (TMH) measurements provided by a new multi-diagnostic platform, and to assess the interobserver reproducibility of TMH measures. Methods Twenty-one healthy eyes of 21 patients (age, 23–65 years) were enrolled. A complete eye examination was performed in all cases with the VX120+ device (Visionix-Luneau Technologies), including an analysis with the new Dry Eye module, performing three consecutive measurements. The within-subject standard deviation (Sw) and Bland–Altman plots were used to assess intersession repeatability. Differences between examiners for TMH were also analysed. Results No statistically significant differences were found between repeated measures of NIBUT (time associated with the first break) and TMH (p > 0.05). However, significant differences were found for NIBUT50% (time associated with half of breaks of the tear film) (p < 0.05). Mean Sw was 0.9 s, 1.4 s and 0.05 mm for NIBUT, NIBUT50% and TMH, respectively. Ranges of agreement between consecutive measures were below 3.5 s and 4.5 s for NIBUT and NIBUT50%, respectively, and below 0.16 mm for TMH. Furthermore, no significant differences were found between examiners in TMH measure, with an inter-examiner range of agreement of 0.12 mm. Conclusions The new dry eye platform of the VX120+ platform evaluated provides objective automated measures of NIBUT and TMH, with acceptable level of intrasession repeatability for clinical screening purposes.
Sponsor: The author David P Piñero has been supported by the Ministry of Economy, Industry and Competitiveness of Spain within the program Ramón y Cajal, RYC-2016-20471.
URI: http://hdl.handle.net/10045/109771
ISSN: 1573-2630
DOI: 10.1007/s10792-020-01470-w
Language: eng
Type: info:eu-repo/semantics/article
Rights: © Springer Nature B.V. 2020
Peer Review: si
Publisher version: https://doi.org/10.1007/s10792-020-01470-w
Appears in Collections:INV - GOPV - Artículos de Revistas

Files in This Item:
Files in This Item:
File Description SizeFormat 
ThumbnailMolina-Martín_etal_2020_IntOphthalmol_final.pdfVersión final (acceso restringido)934,65 kBAdobe PDFOpen    Request a copy


Items in RUA are protected by copyright, with all rights reserved, unless otherwise indicated.