Subjective and objective depth of field measures in pseudophakic eyes: comparison between extended depth of focus, trifocal and bifocal intraocular lenses

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/103292
Full metadata record
Full metadata record
DC FieldValueLanguage
dc.contributorGrupo de Óptica y Percepción Visual (GOPV)es_ES
dc.contributor.authorPalomino-Bautista, Carlos-
dc.contributor.authorSánchez-Jean, Rubén-
dc.contributor.authorCarmona-González, David-
dc.contributor.authorPiñero, David P.-
dc.contributor.authorMolina-Martín, Ainhoa-
dc.contributor.otherUniversidad de Alicante. Departamento de Óptica, Farmacología y Anatomíaes_ES
dc.date.accessioned2020-02-28T12:20:31Z-
dc.date.available2020-02-28T12:20:31Z-
dc.date.issued2019-10-03-
dc.identifier.citationInternational Ophthalmology. 2020, 40: 351-359. doi:10.1007/s10792-019-01186-6es_ES
dc.identifier.issn0165-5701 (Print)-
dc.identifier.issn1573-2630 (Online)-
dc.identifier.urihttp://hdl.handle.net/10045/103292-
dc.description.abstractPurpose: To evaluate different intraocular lens (IOL) designs and to determine whether extended depth of focus (EDOF) lenses provide a higher depth of field (DOF) than the rest considering both subjective and objective measurements. Methods: A total of 100 eyes undergoing cataract surgery were divided into six groups depending on the IOL implanted: bifocal designs were Tecnis ZMB and ZLB (Abbott Laboratories, Illinois, USA), trifocal designs were Finevision (PhysIOL, Liège, Belgium) and AT LISA Tri (Carl Zeiss Meditec., Jena, Germany) and EDOF designs were Symfony (Abbott Laboratories, Illinois, USA) and MiniWell (SIFI MedTech, Catania, Italy). Subjective DOF was obtained from defocus curves for the range of vergences which provide a VA over 0.1 LogMAR and 0.2 LogMAR. Aberrometry was measured and Visual Strehl Optical Transference Function (90%) was used to quantify objectively the DOF. Results: Symfony IOL group showed better subjective and objective DOF compared to the rest of IOL groups, with statistically significant differences (p < 0.001). Comparison between subjective and objective DOF showed that subjective measures were higher for all IOLs, being these differences statistically significant for all groups when compared with objective measures (p < 0.001). Conclusion: Objective and subjective measures of DOF are not comparable due to differences in methodologies and criterions to define the level of degradation acceptance. Nevertheless, both objective and subjective measures demonstrate a greater DOF for EDOF designs compared to bifocal and trifocal IOLs, being the Symfony IOL the one providing higher levels of subjective and objective DOF.es_ES
dc.description.sponsorshipThe author David P Piñero has been supported by the Ministry of Economy, Industry and Competitiveness of Spain within the program Ramón y Cajal, RYC-2016-20471.es_ES
dc.languageenges_ES
dc.publisherSpringer Naturees_ES
dc.rights© Springer Nature B.V. 2019es_ES
dc.subjectDepth of fieldes_ES
dc.subjectDepth of focuses_ES
dc.subjectDefocus curveses_ES
dc.subjectAberrometryes_ES
dc.subjectCataract surgeryes_ES
dc.subjectExtended depth of focus IOLes_ES
dc.subjectPseudophakices_ES
dc.subject.otherÓpticaes_ES
dc.titleSubjective and objective depth of field measures in pseudophakic eyes: comparison between extended depth of focus, trifocal and bifocal intraocular lenseses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.peerreviewedsies_ES
dc.identifier.doi10.1007/s10792-019-01186-6-
dc.relation.publisherversionhttps://doi.org/10.1007/s10792-019-01186-6es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/MINECO//RYC-2016-20471-
Appears in Collections:INV - GOPV - Artículos de Revistas

Files in This Item:
Files in This Item:
File Description SizeFormat 
Thumbnail2020_Palomino-Bautista_etal_IntOphthalmol_final.pdfVersión final (acceso restringido)253,28 kBAdobe PDFOpen    Request a copy


Items in RUA are protected by copyright, with all rights reserved, unless otherwise indicated.