Subjective and objective depth of field measures in pseudophakic eyes: comparison between extended depth of focus, trifocal and bifocal intraocular lenses

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/103292
Información del item - Informació de l'item - Item information
Título: Subjective and objective depth of field measures in pseudophakic eyes: comparison between extended depth of focus, trifocal and bifocal intraocular lenses
Autor/es: Palomino-Bautista, Carlos | Sánchez-Jean, Rubén | Carmona-González, David | Piñero, David P. | Molina-Martín, Ainhoa
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Depth of field | Depth of focus | Defocus curves | Aberrometry | Cataract surgery | Extended depth of focus IOL | Pseudophakic
Área/s de conocimiento: Óptica
Fecha de publicación: 3-oct-2019
Editor: Springer Nature
Cita bibliográfica: International Ophthalmology. 2020, 40: 351-359. doi:10.1007/s10792-019-01186-6
Resumen: Purpose: To evaluate different intraocular lens (IOL) designs and to determine whether extended depth of focus (EDOF) lenses provide a higher depth of field (DOF) than the rest considering both subjective and objective measurements. Methods: A total of 100 eyes undergoing cataract surgery were divided into six groups depending on the IOL implanted: bifocal designs were Tecnis ZMB and ZLB (Abbott Laboratories, Illinois, USA), trifocal designs were Finevision (PhysIOL, Liège, Belgium) and AT LISA Tri (Carl Zeiss Meditec., Jena, Germany) and EDOF designs were Symfony (Abbott Laboratories, Illinois, USA) and MiniWell (SIFI MedTech, Catania, Italy). Subjective DOF was obtained from defocus curves for the range of vergences which provide a VA over 0.1 LogMAR and 0.2 LogMAR. Aberrometry was measured and Visual Strehl Optical Transference Function (90%) was used to quantify objectively the DOF. Results: Symfony IOL group showed better subjective and objective DOF compared to the rest of IOL groups, with statistically significant differences (p < 0.001). Comparison between subjective and objective DOF showed that subjective measures were higher for all IOLs, being these differences statistically significant for all groups when compared with objective measures (p < 0.001). Conclusion: Objective and subjective measures of DOF are not comparable due to differences in methodologies and criterions to define the level of degradation acceptance. Nevertheless, both objective and subjective measures demonstrate a greater DOF for EDOF designs compared to bifocal and trifocal IOLs, being the Symfony IOL the one providing higher levels of subjective and objective DOF.
Patrocinador/es: The author David P Piñero has been supported by the Ministry of Economy, Industry and Competitiveness of Spain within the program Ramón y Cajal, RYC-2016-20471.
URI: http://hdl.handle.net/10045/103292
ISSN: 0165-5701 (Print) | 1573-2630 (Online)
DOI: 10.1007/s10792-019-01186-6
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © Springer Nature B.V. 2019
Revisión científica: si
Versión del editor: https://doi.org/10.1007/s10792-019-01186-6
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2020_Palomino-Bautista_etal_IntOphthalmol_final.pdfVersión final (acceso restringido)253,28 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.