Comparison between MEM and Nott dynamic retinoscopy

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/9631
Información del item - Informació de l'item - Item information
Título: Comparison between MEM and Nott dynamic retinoscopy
Autor/es: Cacho-Martínez, Pilar | García-Muñoz, Ángel | García Bernabeu, José R. | López Navarro, Alberto
Grupo/s de investigación o GITE: Salud Pública
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Enfermería Comunitaria, Medicina Preventiva y Salud Pública e Historia de la Ciencia
Palabras clave: Accommodative response | Accommodative lag | Accommodative lead | Dynamic retinoscopy | Monocular estimate method | Nott retinoscopy
Área/s de conocimiento: Medicina Preventiva y Salud Pública | Óptica
Fecha de creación: abr-1998
Fecha de publicación: sep-1999
Editor: American Academy of Optometry | Lippincott, Williams & Wilkins
Cita bibliográfica: CACHO MARTÍNEZ, Pilar, et al. "Comparison between MEM and Nott dynamic retinoscopy". Optometry and Vision Science. Vol. 76, No. 9 (Sept. 1999). ISSN 1040-5488, pp. 650-655
Resumen: PURPOSE: The aim of this study was to compare MEM dynamic retinoscopy with the Nott method, to discover whether there were different results in the accommodative response and whether a relation exists between the two techniques. METHODS: We performed MEM and Nott dynamic retinoscopy in 50 visually normal university students. Both methods were performed first on the basis of static retinoscopy and second with the result of the subjective refractive exam (binocular balancing). RESULTS: A statistically significant difference existed between the methods. Nott retinoscopy assessed on basis of the subjective refractive exam was the method that obtained the lowest amounts of accommodative lag (+0.42 D), whereas MEM method performed through the static retinoscopy result showed the highest accommodative lag (+0.94 D). Furthermore, correlation analysis showed that a linear relation existed between both methods, so that the Nott value was about one-half the value of the MEM retinoscopy. CONCLUSIONS: MEM dynamic retinoscopy showed greater lag than Nott retinoscopy.
URI: http://hdl.handle.net/10045/9631
ISSN: 1040-5488 (Print) | 1538-9235 (Online)
Idioma: eng
Tipo: info:eu-repo/semantics/article
Revisión científica: si
Aparece en las colecciones:INV - SP - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailComparison between MEM and Nott Dynamic Retinoscopy.pdf531,17 kBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.