Acrylamide-PVA-Eosin photopolymer used as holographic recording material

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/9586
Información del item - Informació de l'item - Item information
Título: Acrylamide-PVA-Eosin photopolymer used as holographic recording material
Autor/es: García Llopis, Celia | Pascual, Inmaculada | Fimia Gil, Antonio
Grupo/s de investigación o GITE: Holografía y Procesado Óptico
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía | Universidad Miguel Hernández. Departamento de Ciencia de Materiales, Óptica y Tecnología Electrónica
Palabras clave: Holography | Holographic recording materials | Photopolymers | Volume holograms | Holographic gratings
Área/s de conocimiento: Óptica | Física Aplicada | Ciencia de Materiales e Ingeniería Metalúrgica
Fecha de creación: 1999
Fecha de publicación: 1-jun-1999
Editor: European Materials Research Society | Elsevier
Cita bibliográfica: GARCÍA LLOPIS, Celia; PASCUAL VILLALOBOS, Inmaculada; FIMIA GIL, Antonio. "Acrylamide-PVA-Eosin photopolymer used as holographic recording material". En: E-MRS European Materials Research Society Spring Meeting [Recurso electrónico] : Symposium J, Materials for Coherent Optics : 1-4 June 1999, Strasbourg, France : CD-ROM proceedings / symposium organizers: M. Grosman, A.I. Larkin, H. Bjelkhagen. Strasbourg : The European Materials Research Society, 1999. pp. J-II.3/1-6
Resumen: New holographic recording materials based on photopolymerizable systems have contributed significantly to the recent growth in the number of holographic applications. In this paper we present the study of a dry film photopolymerizable recording material based on PVA-acrylamides. The photopolymerizable system used consisted of acrylamide as monomer, triethanolamine es radical generator and eosin yellowish as sensitizer. All the components were supported on a film of polyninylalcohol. We estudied the behavior of this photopolymerizable when holographic gratings with a spatial frequency of 1000 lines/mm were stored. The diffraction efficiency and sensitivity were studied for different values of intensity. Diffraction efficiencies of 70% with energetic sensitivities of 200 mJ/cm^2 were obtained using a recording intensity of 7 mW/cm^2.
Patrocinador/es: This work was supported by the "Comisión Interministerial de Ciencia y Tecnología" (CICYT) of Spain under project MAT97-0705-C02-02.
URI: http://hdl.handle.net/10045/9586
Idioma: eng
Tipo: info:eu-repo/semantics/bookPart
Revisión científica: si
Aparece en las colecciones:INV - GHPO - Comunicaciones a Congresos, Conferencias, etc.

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailE-MRS_Estrasburgo_Jii3_1999.pdfVersión final (acceso restringido)433,99 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.