Diffraction efficiency and signal-to-noise ratio of multiplexed volume phase holograms recorded in a photographic emulsion

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/9275
Información del item - Informació de l'item - Item information
Títol: Diffraction efficiency and signal-to-noise ratio of multiplexed volume phase holograms recorded in a photographic emulsion
Autors: Fuentes Rosillo, Rosa | Beléndez, Augusto | Fimia Gil, Antonio
Grups d'investigació o GITE: Holografía y Procesado Óptico
Centre, Departament o Servei: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía | Universidad de Alicante. Departamento de Física, Ingeniería de Sistemas y Teoría de la Señal
Paraules clau: Holography | Holographic recording materials | Volome holograms | Silver halide emulsions
Àrees de coneixement: Física Aplicada | Óptica
Data de creació: 26-de juny-1995
Data de publicació: de juliol-1996
Editor: Springer Berlin / Heidelberg
Citació bibliogràfica: FUENTES ROSILLO, Rosa; BELÉNDEZ VÁZQUEZ, Augusto; FIMIA GIL, Antonio. “Diffraction efficiency and signal-to-noise ratio of multiplexed volume phase holograms recorded in a photographic emulsion”. Applied Physics B: Lasers and Optics. Vol. 63, No. 1 (July 1996). ISSN 0946-2171, pp. 29-34
Resum: The problems related to noise that arise during recording and reconstruction of holograms used in optical data storage or in massive optical interconnection systems are quite similar and can be analyzed in order to improve the quality of the images that these optical systems provide. In this paper, we will analyze noise in cases in which several coherent object waves are simultaneously stored in a phase recording material in a way that allows us to obtain information about the relationship that exists between the recording material and the number of waves that are being stored. The material used in this study is Agfa Gevaert 8E75 HD holographic film processed with a rehalogenating—type bleach bath without a fixation step. Additionally, we show experimentally that it is possible to holographically store more than 400 waves at the same time (in a coherent fashion) using the same storage geometry, with a signal-to-noise ratio larger than 20 and an average diffraction efficiency of 15%.
Patrocinadors: Part of this work was supported by the Direcció General d'Ensenyaments Universitaris i Investigació of the Generalitat Valenciana, Spain (Project GV-1165/93) and the Comisión Interministerial de Ciencia y Tecnología, Spain (Project MAT93-0369).
URI: http://hdl.handle.net/10045/9275
ISSN: 0946-2171 (Print) | 1432-0649 (Online)
DOI: 10.1007/BF01112833
Idioma: eng
Tipus: info:eu-repo/semantics/article
Drets: The original publication is available at www.springerlink.com
Revisió científica: si
Versió de l'editor: http://dx.doi.org/10.1007/BF01112833
Apareix a la col·lecció: INV - GHPO - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
ThumbnailAPB_v63_n1_p29_1996.pdfVersión final (acceso restringido)640,09 kBAdobe PDFObrir     Sol·licitar una còpia
ThumbnailAPB_v63_n1_p29_1996pre.pdfVersión revisada (acceso libre)1,22 MBAdobe PDFObrir Vista prèvia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.