Triplet design as an intraocular lens for high myopia

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/9169
Información del item - Informació de l'item - Item information
Título: Triplet design as an intraocular lens for high myopia
Autor/es: González Pérez, Concepción | Carretero López, Luis | Pascual, Inmaculada | Fimia Gil, Antonio
Grupo/s de investigación o GITE: Holografía y Procesado Óptico
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Intraocular lenses | High myopia | Triplet | Matrix methods | Optical properties
Área/s de conocimiento: Óptica
Fecha de creación: 6-ago-1993
Fecha de publicación: 1-jun-1995
Editor: Optical Society of America
Cita bibliográfica: GONZÁLEZ PÉREZ, Concepción, et al. "Triplet design as an intraocular lens for high myopia". Applied Optics. Vol. 34, No. 16 (June 1995). ISSN 0003-6935, pp. 2898-2907
Resumen: We present the possibility of using a triplet as an intraocular lens (IOL). The matrix method was used to calculate the power of this triplet for high myopia. The thickness of the lens, the distances between the edges of the IOL and the endothelium, the distances between the edges of the IOL and the iris, and the influence of axial displacement have been analyzed. We have also compared the size, the thickness, the power, the distances between the edges of the IOL and the endothelium, and the distances between the edges of the IOL and the iris to the typical concave-plane lens that is usually implanted in highly myopic eyes. As we can see, when the anterior chamber depth is normal, our triplet presents a better geometrical form than the concave-plane lens.
URI: http://hdl.handle.net/10045/9169
ISSN: 0003-6935 (Print) | 1539-4522 (Online)
DOI: 10.1364/AO.34.002898
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: This paper was published in Applied Optics and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-34-16-2898. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law.
Revisión científica: si
Aparece en las colecciones:INV - GHPO - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailAO_v34_n16_p2898_1995.pdf139,94 kBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.