Concurrent validity and reliability of proprietary and open-source jump mat systems for the assessment of vertical jumps in sport sciences

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/81052
Registro completo de metadatos
Registro completo de metadatos
Campo DCValorIdioma
dc.contributorResearch in Physical Education, Fitness and Performance (RIPEFAP)es_ES
dc.contributor.authorPueo, Basilio-
dc.contributor.authorJimenez-Olmedo, Jose Manuel-
dc.contributor.authorLipinska, Patrycja-
dc.contributor.authorBuśko, Krzysztof-
dc.contributor.authorPenichet-Tomás, Alfonso-
dc.contributor.otherUniversidad de Alicante. Departamento de Didáctica General y Didácticas Específicases_ES
dc.date.accessioned2018-10-01T10:23:36Z-
dc.date.available2018-10-01T10:23:36Z-
dc.date.issued2018-
dc.identifier.citationActa of Bioengineering and Biomechanics. 2018, 20(3): 51-57. doi:10.5277/ABB-01132-2018-02es_ES
dc.identifier.issn1509-409X (Print)-
dc.identifier.issn10.5277/ABB-01132-2018-02-
dc.identifier.issn2450-6303 (Online)-
dc.identifier.urihttp://hdl.handle.net/10045/81052-
dc.description.abstractPurpose: Vertical jump tests are used to assess lower-limb power of athletes in sport sciences. Flight time measurement with jump-mat systems is the most common procedure for this purpose. The aim of this study was to analyze the concurrent validity and reliability of two proprietary systems (Globus and Axon) and an open-source system (Chronojump). Methods: A conditioning electric circuit governed by a controlled wave generator is designed to substitute athletes jumping on a physical mat. In order to look for possible differences associated to timekeeping by each microcontroller device, all three systems are fed by the circuit simultaneously. Results: Concurrent validity was high for the three systems. Standarized typical error of estimate (TEE) was trivial, according to MBI interpretation, as well as perfect Pearson correlation coefficient. Reliability was assessed using coefficient of variation of flight time measure, resulting in 0.17–0.63% (0.05–0.12 cm) for Globus, 0.01% (0.09 cm) for Chronojump and 5.65–9.38% (2.15–3.53 cm) for Axon. These results show that all jump-mat system produced nearly identical measures of flight time so they can be considered valid and reliable for practical purposes. In comparison, Chronojump showed the best performance whereas Axon showed enough variability and disagreement to pose a problem in testing elite athletes. Conclusions: These experiments show that open-source jump mats are as valid and reliable as their proprietary counterparts at a lower cost. Therefore, practitioners can be confident in using Globus or Chronojump systems to test athletes’ jump height because of their negligible errors and Axon system to monitor general population.es_ES
dc.languageenges_ES
dc.publisherWroclaw University of Technology. Faculty of Mechanical Engineeringes_ES
dc.rights© Acta of Bioengineering and Biomechanicses_ES
dc.subjectAthletees_ES
dc.subjectJumpes_ES
dc.subjectOpen-hardwarees_ES
dc.subjectSportses_ES
dc.subjectSwitches_ES
dc.subjectTestes_ES
dc.subject.otherEducación Física y Deportivaes_ES
dc.titleConcurrent validity and reliability of proprietary and open-source jump mat systems for the assessment of vertical jumps in sport scienceses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.peerreviewedsies_ES
dc.relation.publisherversionhttps://doi.org/10.5277/ABB-01132-2018-02es_ES
dc.identifier.cvIDA9358695-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
Aparece en las colecciones:INV - HEALTH-TECH - Artículos de Revistas
INV - SCAPE - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2018_Pueo_etal_ActaBioengBiomech.pdf347,95 kBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.