Concurrent validity and reliability of proprietary and open-source jump mat systems for the assessment of vertical jumps in sport sciences

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/81052
Información del item - Informació de l'item - Item information
Title: Concurrent validity and reliability of proprietary and open-source jump mat systems for the assessment of vertical jumps in sport sciences
Authors: Pueo, Basilio | Jimenez-Olmedo, Jose Manuel | Lipinska, Patrycja | Buśko, Krzysztof | Penichet-Tomás, Alfonso
Research Group/s: Research in Physical Education, Fitness and Performance (RIPEFAP)
Center, Department or Service: Universidad de Alicante. Departamento de Didáctica General y Didácticas Específicas
Keywords: Athlete | Jump | Open-hardware | Sports | Switch | Test
Knowledge Area: Educación Física y Deportiva
Issue Date: 2018
Publisher: Wroclaw University of Technology. Faculty of Mechanical Engineering
Citation: Acta of Bioengineering and Biomechanics. 2018, 20(3): 51-57. doi:10.5277/ABB-01132-2018-02
Abstract: Purpose: Vertical jump tests are used to assess lower-limb power of athletes in sport sciences. Flight time measurement with jump-mat systems is the most common procedure for this purpose. The aim of this study was to analyze the concurrent validity and reliability of two proprietary systems (Globus and Axon) and an open-source system (Chronojump). Methods: A conditioning electric circuit governed by a controlled wave generator is designed to substitute athletes jumping on a physical mat. In order to look for possible differences associated to timekeeping by each microcontroller device, all three systems are fed by the circuit simultaneously. Results: Concurrent validity was high for the three systems. Standarized typical error of estimate (TEE) was trivial, according to MBI interpretation, as well as perfect Pearson correlation coefficient. Reliability was assessed using coefficient of variation of flight time measure, resulting in 0.17–0.63% (0.05–0.12 cm) for Globus, 0.01% (0.09 cm) for Chronojump and 5.65–9.38% (2.15–3.53 cm) for Axon. These results show that all jump-mat system produced nearly identical measures of flight time so they can be considered valid and reliable for practical purposes. In comparison, Chronojump showed the best performance whereas Axon showed enough variability and disagreement to pose a problem in testing elite athletes. Conclusions: These experiments show that open-source jump mats are as valid and reliable as their proprietary counterparts at a lower cost. Therefore, practitioners can be confident in using Globus or Chronojump systems to test athletes’ jump height because of their negligible errors and Axon system to monitor general population.
URI: http://hdl.handle.net/10045/81052
ISSN: 1509-409X (Print) | 10.5277/ABB-01132-2018-02 | 2450-6303 (Online)
Language: eng
Type: info:eu-repo/semantics/article
Rights: © Acta of Bioengineering and Biomechanics
Peer Review: si
Publisher version: https://doi.org/10.5277/ABB-01132-2018-02
Appears in Collections:INV - HEALTH-TECH - Artículos de Revistas
INV - SCAPE - Artículos de Revistas